baxi boiler keeps coming on with cold water

baxi boiler keeps coming on with cold water

Author
Discussion

wjwren

Original Poster:

4,484 posts

135 months

Thursday 25th August 2016
quotequote all
I keep hearing the boiler come on when i turn a cold tap on or the cold only washing machine fills up. Its a Baxi combi 33 HE.

wjwren

Original Poster:

4,484 posts

135 months

Thursday 25th August 2016
quotequote all
just checked and no gas is being used

LookAtMyCat

464 posts

108 months

Thursday 25th August 2016
quotequote all
Fit a shock arrestor. The cold supply opening/closing is triggering the flow-switch on the boiler.

richatnort

3,021 posts

131 months

Friday 26th August 2016
quotequote all
Get a plumber out who will tell you it's knackered and you need to get a new one laugh

Rickyy

6,618 posts

219 months

Friday 26th August 2016
quotequote all
What Lookatmycat said. Things like washing machines and quarter turns taps shut off the water supply instantly. the sudden build up of pressure sends a 'shockwave' through the pipework and can trigger a sensitive flow switch.