Dimmer switch for a multi bulb lamp

Dimmer switch for a multi bulb lamp

Author
Discussion

ReaderScars

Original Poster:

6,087 posts

176 months

Monday 16th January 2017
quotequote all
I'd like to incorporate a dimmer switch into a 240v lamp base which features x4 20w bulbs.

It seems that using the module out of a wall dimmer for ceiling lights isn't an appropriate type - or if it is, could someone please explain in (very) simple terms how to wire up the x4 lives, x4 neutrals from the bulb holders (earths are combined and connected to the metal lamp base).

The module I've got is 1 in, 1 out - I think I need x2 in+out?

Any suggestions or recommendations for dimmer modules please?

speedyman

1,525 posts

234 months

Monday 16th January 2017
quotequote all
Without the exact details of the dimmer you intend to use. Just connect the live supply from the plug (1 Brown) to Common terminal on dimmer switch, all four lives from the lamps (4 Browns) connected to load (L1) on dimmer switch.

Neutrals (5 Blues) connected togeather using a connector block. Do not connect them to the switch.



ReaderScars

Original Poster:

6,087 posts

176 months

Monday 16th January 2017
quotequote all
OK, will do - thanks for the clear explanation. Don't feel too bad if I don't post for a while - I won't blame you.

ReaderScars

Original Poster:

6,087 posts

176 months

Monday 16th January 2017
quotequote all
Works great - thanks. Multi tester seems to indicate everything's earthed, looks like it's safe to take the rubber gloves off.