boiler keeps getting air locks, why?

boiler keeps getting air locks, why?

Author
Discussion

darren f

982 posts

213 months

Wednesday 26th January 2011
quotequote all
Apologies for continuing the thread, but we had a similar issue before Xmas and I'm intrigued....

So he shorted the boiler stat and crowded hot water through the primary on the HW cylinder (I assume that's what is meant by 'boiling the cylinder'?). Which, if you got hot water suggests the primary flow to the cylinder is not sludged up? Which then suggests the problem could be as simple / cheap as a duff motorised valve maybe? Probably not helped by poor pipe routing into the cylinder. (Which having seen it is probably why your plumber has condemned most of it) frown

We went through all these possibles when our system produced no 'boiler sourced' HW- our problem turned out to be a completely sludged CW supply to the primary circuit on the HW cylinder- we couldn't get any HW through the cylinder primary at all.

Unless your boiler is on its last legs and/or you are dead set on changing it I'd be inclined to tidy up the pipework / valves etc first and see what occurs. Bolting a new boiler onto an existing system could possibly throw up more issues (especially if the original install was a bad as it seems). But then I'm a cheapskate (hence, no Fernox in our system and the resultant sludging cry)

dave144

Original Poster:

261 posts

170 months

Friday 28th January 2011
quotequote all
How do you short the stat? I wasn't around when he sorted it.

As you say I don't think there was any sludge in the system but because the cold water tank isn't high enough above the cylinder it will keep drawing in air. The tank is as high you can go, so where to got from here??

eskidavies73

5,374 posts

159 months

Friday 28th January 2011
quotequote all
the primary flow from boiler should rise all way from boler to cylinder the slightest backfall and the system wont gravitate and complete circuit any run vertical should rise .ideal senario is airing cupboard above boiler primary straight into cylinder if primary run across floor then slight fall back if you know what i mean you to over come this and turn it to fully pumped system providing its not a primatic cylinder if this sounds like double dutch then your plumber mate should explain

eskidavies73

5,374 posts

159 months

Friday 28th January 2011
quotequote all
dave144 said:
How do you short the stat? I wasn't around when he sorted it.

As you say I don't think there was any sludge in the system but because the cold water tank isn't high enough above the cylinder it will keep drawing in air. The tank is as high you can go, so where to got from here??
you got a backfall in the flow pipe make it rise to cylinder problem solved telling you

Paul Drawmer

4,878 posts

267 months

Friday 28th January 2011
quotequote all
eskidavies73 said:
the primary flow from boiler should rise all way from boler to cylinder the slightest backfall and the system wont gravitate and complete circuit any run vertical should rise .ideal senario is airing cupboard above boiler primary straight into cylinder if primary run across floor then slight fall back if you know what i mean you to over come this and turn it to fully pumped system providing its not a primatic cylinder if this sounds like double dutch then your plumber mate should explain
Hic!

dave144

Original Poster:

261 posts

170 months

Thursday 3rd February 2011
quotequote all
The cold water tank.



Doesn't look pretty does it?


Not a simple fix

Still waiting on the wife's uncle to get us a quote...family for you

eskidavies

5,374 posts

159 months

Thursday 3rd February 2011
quotequote all
no wonder it dont fking work that a proper mish mash

dave144

Original Poster:

261 posts

170 months

Sunday 6th February 2011
quotequote all
Quick update. Another week another air lock and no hot water. Sorted it myself today by turning off the CH and switching on the hot water pump without the thermocouple fitted for about 20 mins . Not the best solution but it sure as hell worked.