Virtualising Domain Controllers?

Virtualising Domain Controllers?

Author
Discussion

paddyhasneeds

Original Poster:

51,639 posts

211 months

Saturday 24th July 2010
quotequote all
I already have one of our Domain Controllers virtualised, and now our other (FSMO master) is due to be replaced.

IMO our ESX cluster gives us a lot more resiliency then a single physical server, so I'd like to virtualise this one as well.

Just curious how many of you have fully virtual DC's these days and if you've encountered any problems?

paddyhasneeds

Original Poster:

51,639 posts

211 months

Saturday 24th July 2010
quotequote all
lestag said:
Have you read these?
http://support.microsoft.com/kb/888794
http://support.microsoft.com/kb/897615

I have not done a fully virtual AD, but I would see the basic physical principles apply,dont put all your eggs in one basket. I would be hesitant to have all DCs on the one SAN incase of SAN failure, especially if you have other servers not on the SAN that are reliant on AD access.
I would keep a DC virtualised on a basic ESXi server in case of failure of the SAN (rare but ...eventful when it happens)

but hey , im parinoid.... :geek:
Yes I had already read those but thank you. Seemed to come down to common sense with no glaring "Do not do this" items.

We currently have two SANs in two locations on our site so I'd be looking at having one virtualised DC in each location ideally.

Personally I'm paranoid as well, but I'm leaning towards the DR and ESX functionality outweighing having a DC running on a single physical box.

Point taken on SAN failure, but being blunt if that fails I've got way bigger problems than if people can't log on for a while smile

paddyhasneeds

Original Poster:

51,639 posts

211 months

Sunday 25th July 2010
quotequote all
Be interested to hear more on the time issues you've encountered as I can't say we've encountered it and most guides seem to suggest it's less of an issue these days if you do the time sync the recommended way etc.

paddyhasneeds

Original Poster:

51,639 posts

211 months

Monday 26th July 2010
quotequote all
agent006 said:
paddyhasneeds said:
Be interested to hear more on the time issues you've encountered as I can't say we've encountered it and most guides seem to suggest it's less of an issue these days if you do the time sync the recommended way etc.
We didn't get any issues as we did it the recommended way smile
Ahh sorry I misunderstood. I'm doing it the (hopefully) foolproof way and setting the FSMO VM to point to external NTP same as I did the physical one.

paddyhasneeds

Original Poster:

51,639 posts

211 months

Monday 26th July 2010
quotequote all
pantscat said:
paddyhasneeds said:
... most guides seem to suggest it's less of an issue these days if you do the time sync the recommended way etc.
What is the recommended way?

I've yet to virtualise my DCs as yet, but I will definitely do this when I update to 2008 R2...
Have your FSMO Master sync using external NTP like you would a physical box rather than using vmware tools time sync.

You may know but if you're still on ESX 3.5 there's an issue with 2008 R2 and the SVGA driver the tools install by default.