Fuel Sender Unit - fitting ?
Fuel Sender Unit - fitting ?
Author
Discussion

rev-erend

Original Poster:

21,619 posts

313 months

Wednesday 2nd November 2005
quotequote all
Has anyone fitted a fuel sender unit on a 400SE - I presume
once you remove the wires then the unit just turns until you
find the slot and you then pull it out..

pwd95

8,452 posts

267 months

Wednesday 2nd November 2005
quotequote all
I think mine's gone (reading full all the time) so I'll be interested in this too

adam quantrill

11,679 posts

271 months

Wednesday 2nd November 2005
quotequote all
Mine reads empty sometimes when it's about 2/3 full. Must be a bad connection on the pot just at that point. So I'm also interested in how easy it is to get them out and back in...

uglymug

575 posts

264 months

Wednesday 2nd November 2005
quotequote all
Hi all, I had the same problem with mine(350i). Took the fuel sender out, and took the cover off the resistor bit. Found it was the fine wire had broke. Very fiddly bit- soldered it together. Spank my ar*e and call me Charlie, it now works great. Form an orderly queue!

l33

3,469 posts

253 months

Wednesday 2nd November 2005
quotequote all
Nice on Charlie!
Not sure about spanking your ar5e though...

How easy is the fuel sender to get at? I also have problems with mine (reads empty when actually 1/2 full)
Cheers,
L33.

uglymug

575 posts

264 months

Wednesday 2nd November 2005
quotequote all
Quite straight forward if you have a pit.

rev-erend

Original Poster:

21,619 posts

313 months

Wednesday 2nd November 2005
quotequote all
uglymug said:
Hi all, I had the same problem with mine(350i). Took the fuel sender out, and took the cover off the resistor bit. Found it was the fine wire had broke. Very fiddly bit- soldered it together. Spank my ar*e and call me Charlie, it now works great. Form an orderly queue!


That's interesting - might have to look out for that but the main reason for doing the job is
that it's leaking loads of 4* .. and I don't fancy welding anywhere near a gallon on fuel of the floor

shpub

8,507 posts

301 months

Thursday 3rd November 2005
quotequote all
On the 520 the sender was boilted in and used a cork gasket to provide the seal.
The gaskets are no longer available and I had to make one.
I also took the opportunity to calibrate the thing by bending the arm so that it went to zero only when it touched the tank floor.

rev-erend

Original Poster:

21,619 posts

313 months

Thursday 3rd November 2005
quotequote all
What did you make the gasket out of Steve ?

shpub

8,507 posts

301 months

Thursday 3rd November 2005
quotequote all
err as it was a cork gasket I used err cork...


Any good motor factor should sell the stuff.

rev-erend

Original Poster:

21,619 posts

313 months

Thursday 3rd November 2005
quotequote all
Thanks Steve..