My engine cooling fan seems to have stopped working. I've checked the fuse which looked okay and replaced it, it doesn't seem to have made any difference.

I think it was the right fuse, the car has 3 rows of 7 fuses which I think is the layout from the 400SE, I only have a photocopy of the fuse board layout that came with the car. This lists the fan fuse as number 20 (third row, one in from the right). It was a 25 amp fuse. I'll check the other fuses tomorrow just in case.

If it isn't the fuse, how can I diagnose what it is likely to be?

350zwelgje

1,820 posts

290 months

Tuesday 8th May 2007
quotequote all
Put two leads to the fan motor, or bypass the switch, to check if they can work. If not it could be something like the fan motor has packed up.

I have only 20 amp fuse for the fan. But it is a single fan setup. And if with two it would be the same I don't know.

Rob

cdt

Original Poster:

537 posts

311 months

Tuesday 8th May 2007
quotequote all
Mine is a single fan, is that normal with a 3.9 litre engine?

Can I just connect the fan motor directly to the battery terminals?

cdt

Original Poster:

537 posts

311 months

Wednesday 9th May 2007
quotequote all
Strange, the fans are working now ...

All I did was turn the fan each way a few times by hand and wiggled the wires a little. The fan did feel a little stiff to turn.

If you are standing in front of the car facing the fan, should the fan be turned clockwise or anti-clockwise?

Would it be an idea to spray any of it with WD40?

rev-erend

21,620 posts

313 months

Wednesday 9th May 2007
quotequote all
Check the lead to the fan - one should show a voltage of 12 volts - the other is a negative and is switched to earch when the engine temp needs it.

If you earth the other wire then the fan should work.. unless there is a problem with the fan of course.

You can also run seperate + and - wires to the fan - this is what I've done in the past to check if a fan is at fault.

chunder

785 posts

275 months

Wednesday 9th May 2007
quotequote all
cdt said:
Strange, the fans are working now ...

All I did was turn the fan each way a few times by hand and wiggled the wires a little. The fan did feel a little stiff to turn.

If you are standing in front of the car facing the fan, should the fan be turned clockwise or anti-clockwise?

Would it be an idea to spray any of it with WD40?


As long as the fan sucks air in from the front and sucks / blows over the radiator then it doesn't matter which way it actually spins !

Spraying it probably won't help as it should be sealed and getting anything into the bearing requires disassembly.

Aside from the fuse it will probably be supplied via a relay - intermittent relay operation isn't unheard of.

As in many previous posts / SH bible an override switch isn't a bad idea.

cdt

Original Poster:

537 posts

311 months

Wednesday 9th May 2007
quotequote all
chunder said:
cdt said:
Strange, the fans are working now ...

All I did was turn the fan each way a few times by hand and wiggled the wires a little. The fan did feel a little stiff to turn.

If you are standing in front of the car facing the fan, should the fan be turned clockwise or anti-clockwise?

Would it be an idea to spray any of it with WD40?


As long as the fan sucks air in from the front and sucks / blows over the radiator then it doesn't matter which way it actually spins !

Spraying it probably won't help as it should be sealed and getting anything into the bearing requires disassembly.

Aside from the fuse it will probably be supplied via a relay - intermittent relay operation isn't unheard of.

As in many previous posts / SH bible an override switch isn't a bad idea.


Thanks for the replies

I was just wondering if I turned it the wrong way by hand if I could damage it.

If the problem isn't related to the otter switch, does a fan override switch help at all?




Edited by cdt on Wednesday 9th May 19:35

350zwelgje

1,820 posts

290 months

Wednesday 9th May 2007
quotequote all
Seems something fan internal to me. Turning it by hand probably cleared a few internal contacts and fixed it...
And you are right, if the fan (motor) itself has a problem an override switch won't help.

Rob