Hi Guys,
I have an electrical issue with my 400SE. The centre dials dont work or the indicators or the warning lights. They all seem to share the same 12v and I have measured he voltage at the voltmeter with my multimeter at 1.3V. I am puzzled to say the least. Has anyone out there got a wiring diagram for a 400 as the one in the bible doesnt match mine, I guess for a 350i. Or better still any ideas?
Cheers
OFB
I have an electrical issue with my 400SE. The centre dials dont work or the indicators or the warning lights. They all seem to share the same 12v and I have measured he voltage at the voltmeter with my multimeter at 1.3V. I am puzzled to say the least. Has anyone out there got a wiring diagram for a 400 as the one in the bible doesnt match mine, I guess for a 350i. Or better still any ideas?
Cheers
OFB
Where did you take your measurement from? make sure that you get a good earth, preferably direct from the battery - if you took the measurement from the same earth used by the same circuit you may be measuring a differencial voltage because of a poor earth.
Failing this, if your getting a residual voltage its is likely that you have a poor connector creating a high resistance - so, first principles, check the circuit earth - then check the supply to the fuse and work backwards.
Failing this, if your getting a residual voltage its is likely that you have a poor connector creating a high resistance - so, first principles, check the circuit earth - then check the supply to the fuse and work backwards.