Programming Meta M36 Immobiliser Plinkers
Discussion
This worked for me
www.abacuscaralarms.co.uk/alarms/remote_controls/meta-remotes.html
1 Arm and disarm the alarm sixteen times or until the alarm stops responding, alarm now in program mode.....
2 Once in program mode press the button of the new remotes(s), press the button of the original remote(s). This must be done within 8 seconds of each action. If 8 seconds pass without any actions the alarm will automatically exit programming mode and you will have to start from step 1.
3 Wait 8 seconds to exit learning mode.
4 Test remotes.
www.abacuscaralarms.co.uk/alarms/remote_controls/meta-remotes.html
1 Arm and disarm the alarm sixteen times or until the alarm stops responding, alarm now in program mode.....
2 Once in program mode press the button of the new remotes(s), press the button of the original remote(s). This must be done within 8 seconds of each action. If 8 seconds pass without any actions the alarm will automatically exit programming mode and you will have to start from step 1.
3 Wait 8 seconds to exit learning mode.
4 Test remotes.
Edited by puffsorted2 on Friday 9th February 12:52
OK, just spoke to Carl and got the new plinker working having got a key cut
FYI, the sequence is:
* Insert original plinker into hole
* Switch ignition to ACC
* Wait four seconds
* Switch off ignition
* Insert new plinker into hole and hold for 2 seconds
And voila, a newly programmed plinkerette.
FYI, Carl was telling me that the M36 has five "slots" for programming, the first two are used by the originally programmed keys, the 3rd is used for the optional alarm interface, so two spare are available for use. After that you have to get the immobiliser reprogrammed.
FYI, the sequence is:
* Insert original plinker into hole
* Switch ignition to ACC
* Wait four seconds
* Switch off ignition
* Insert new plinker into hole and hold for 2 seconds
And voila, a newly programmed plinkerette.
FYI, Carl was telling me that the M36 has five "slots" for programming, the first two are used by the originally programmed keys, the 3rd is used for the optional alarm interface, so two spare are available for use. After that you have to get the immobiliser reprogrammed.