dave_s13 said:
On a similar note, my boiler needs topping up every now and then via the quick fill loop. That can't be normal? Where's the bloody water go? No obvioius leaks anywhere?
Soz fo the thread hijack but you kinda got yours answered and I couldn't be arsed sarting a new one
Amongst other things, water has oxygen in it. So when the water circulates it is bled out of the system via the automatic bleed valve within the boiler.
robinhood21 said:
dave_s13 said:
On a similar note, my boiler needs topping up every now and then via the quick fill loop. That can't be normal? Where's the bloody water go? No obvioius leaks anywhere?
Soz fo the thread hijack but you kinda got yours answered and I couldn't be arsed sarting a new one
Amongst other things, water has oxygen in it. So when the water circulates it is bled out of the system via the automatic bleed valve within the boiler.
Oh yeah! I shoulda thought of that really. Cheers.
robinhood21 said:That's not strictly true. Driving oxygen out of water isn't that easy and certainly not all boilers have an auto air vent in them.
dave_s13 said:
On a similar note, my boiler needs topping up every now and then via the quick fill loop. That can't be normal? Where's the bloody water go? No obvioius leaks anywhere?
Soz fo the thread hijack but you kinda got yours answered and I couldn't be arsed sarting a new one
Amongst other things, water has oxygen in it. So when the water circulates it is bled out of the system via the automatic bleed valve within the boiler.
If you are losing pressure it is MOST likely that you have a leak....
Pipework under floors if a possibility, leaking heat exchangers in the boiler lose water that is instantly vapourised and ejected from the flue...
'Air' in radiators is most commonly hydrogen as mentioned above, although it can be drawn in on the suction side of the pump if you have a small leak there.
Central Heating water has no free oxygen to rust stuff and is virtually inert. The problem comes if a leak allows the topping up with fresh oxygenated water or in an open vented system 'Pumping over' can re-oxygenate.
By the way, vent downstairs first. This way there is less chance of the air moving upstairs once you have bled the upstairs. I always bleed with the pump running and if there is a lot of air in the pipework I turn off all the radiators and open one at a time, closing the previous one to clear the runs fully.