Help - how do I bleed radiators?!
Help - how do I bleed radiators?!
Author
Discussion

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
Just bled 2 radiators in my flat that were stone cold. Loads of air came out and they heated up, but the water pump in the boiler started making a whining sound about 10 minutes later and the radiators have gone cold again. Have I done it wrong?

Cheers!
P

Davi

17,153 posts

251 months

Wednesday 22nd March 2006
quotequote all
Sounds a bit odd. You might want to check that the header tank has some water in it if you have one, make sure the ballcock isn't stuck - might just be getting more air sucked in.

Other than that, bleed all the rads as you have been doing, and check if the pump has a bleed on it - ours you removed a big screw out the end of the pump. Only other thing is if the pump speed isn't right it can resonate.

>> Edited by Davi on Wednesday 22 March 20:16

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
It's a combi boiler, so no tank. The noise has stopped now, but the radiators are still cold!

nonegreen

7,803 posts

301 months

Wednesday 22nd March 2006
quotequote all
Is it a combi boiler? If so you need to top up and pressurise the system then bleed it. The noise in the pump is probably air cavitating. Technique is to pressurise, bleed then repressurise to ensure the system is full. HTH

Davi

17,153 posts

251 months

Wednesday 22nd March 2006
quotequote all
paulie-mafia said:
It's a combi boiler, so no tank. The noise has stopped now, but the radiators are still cold!


Have you tried re-bleeding them?

puggit

49,832 posts

279 months

Wednesday 22nd March 2006
quotequote all
nonegreen said:
Is it a combi boiler? If so you need to top up and pressurise the system then bleed it. The noise in the pump is probably air cavitating. Technique is to pressurise, bleed then repressurise to ensure the system is full. HTH


I made this mistake at the start of the winter season.

Go top up the pressure in the water system

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
nonegreen said:
Is it a combi boiler? If so you need to top up and pressurise the system then bleed it. The noise in the pump is probably air cavitating. Technique is to pressurise, bleed then repressurise to ensure the system is full. HTH


Ahhhhh.... That makes sense now! Pressure needle is showing 0 bar! There are 5 identical taps underneath - time to root the manual out.

Thanks!

jamieboy

5,932 posts

260 months

Wednesday 22nd March 2006
quotequote all
Beside our big boiler, there's a little expansion tank with a valve on it and a dial which is green about three-quarters of the way round, then red. Every time I bleed the radiators, I open the valve until the needle goes to the middle of the green section, then close it.

I've got no real idea what it does, but I get a great sense of DIY-satisfaction from doing it.

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
AGHH!!! The book says call a service engineerand the hot water's gone off too! There are 5 identical taps underneath, preume it's a combination. Any ideas? Boiler is a Baxi 105e

puggit

49,832 posts

279 months

Wednesday 22nd March 2006
quotequote all
When I did this I needed to reset the boiler using a little switch on top - it was all in the manual (totally different make of boiler).

There are also some great online plumbing forums which helped.

john_p

7,073 posts

281 months

Wednesday 22nd March 2006
quotequote all
Have you topped up the system? 0 bar is no good. There should be a pipe connecting the cold water feed into the central heating circuit (supposed to be a removable loop of pipe, but they are usually left in). Open this up until the boiler shows 1.5bar or so. Then it should work.

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
Sorted - lucky find with one of the taps!

What a to-do!

z4monster

1,442 posts

291 months

Wednesday 22nd March 2006
quotequote all
Usually there is a remmoveable pipe which fills the system from the mains water supply. I think this has to be made removable for legal reasons but often isnt disconnected. One you turn the tap, watch the needle rise and keep it within the reuired range. Don't fill it to the top of the dial as this is too much pressure when it gets hot and will blow off pressure as a safety thing.
Usually about 1.3 bar is right But see your manual. Once the pressure is back on then the hot water will work too. You may need to reset the unit by cycling the power but hopefully not.

Davi

17,153 posts

251 months

Wednesday 22nd March 2006
quotequote all
paulie-mafia said:
Sorted - lucky find with one of the taps!

What a to-do!



Paulie - just called a mate for you but you appear to have found it anyway - he said that if the guage was at zero pressure it could also indicate a leak in the system, so to watch it carefully for a while, especially if it starts to drop again.

paulie-mafia

Original Poster:

3,321 posts

254 months

Wednesday 22nd March 2006
quotequote all
Thanks very much guys

woody

2,189 posts

315 months

Wednesday 22nd March 2006
quotequote all
Once you've topped the system up you will need to bleed the radiators - but do this when they are cold.
Once you've bled them you will probably have to top it up again.

Hope this helps.

Chris

vipers

33,525 posts

259 months

Wednesday 22nd March 2006
quotequote all
If your taps run hot, but your radiators dont, could be the diverter valve, they gunge up sometimes, best bet is to call a plumber..

After you have paid the hefty bill, consider coming onboard the British Gas 5 star cover, covers everything to do with your water system, even coveres replacement of leaking rads.

Well worth it.