quotequote all
Evening All,

Quick question for the PH Plumbers we have an Aqualisa Power Shower at home which doesn't work correctly. It was a replacement for another Aqualisa shower which died after many years of abuse!

When you first start having a shower its fine but water soon stops flowing, i'm then left standing in the freezing cold waiting for the water to reappear (after 30-60secs to a minute it does return). The pump is still making a noise even when there is no water flowing.

My guess is that its been installed incorrectly and that the hot water feed to the shower has been installed at the top of the tank rather than at the bottom. (eg. the tank has to refill up to a certain level in order for water to come out of the shower head?)

I have heard that there is 2 feeds to the shower (which may or not be correct?) is it just a case that these feeds are round the wrong way and that I can just swap them over? We never had this problem with the old shower which was in the same position as the current one.


Second question.......

We live in the Chilterns and the water is full of chalk so after a while everything starts to clog up. Is there anything we can flush the pipes out with? The hot water tap on the bath is obviously suffering having been installed 10 years ago so it takes forever to run a bath!


Thanks everyone! Have a good weekend!


Phill

esselte

14,626 posts

298 months

Friday 31st March 2006
quotequote all
pmanson said:
Evening All,

Quick question for the PH Plumbers we have an Aqualisa Power Shower at home which doesn't work correctly. It was a replacement for another Aqualisa shower which died after many years of abuse!

When you first start having a shower its fine but water soon stops flowing, i'm then left standing in the freezing cold waiting for the water to reappear (after 30-60secs to a minute it does return). The pump is still making a noise even when there is no water flowing.

My guess is that its been installed incorrectly and that the hot water feed to the shower has been installed at the top of the tank rather than at the bottom. (eg. the tank has to refill up to a certain level in order for water to come out of the shower head?)

I have heard that there is 2 feeds to the shower (which may or not be correct?) is it just a case that these feeds are round the wrong way and that I can just swap them over? We never had this problem with the old shower which was in the same position as the current one.


Second question.......

We live in the Chilterns and the water is full of chalk so after a while everything starts to clog up. Is there anything we can flush the pipes out with? The hot water tap on the bath is obviously suffering having been installed 10 years ago so it takes forever to run a bath!


Thanks everyone! Have a good weekend!


Phill


Surely the hot water must come from the top of the tank otherwise you'd get cold water instead?

ferg

15,242 posts

288 months

Friday 31st March 2006
quotequote all
I would suspect the ballvalve in the roof tank is not keeping up with the water being pumped out of the bottom. Fit a new one for 4 or 5 quid.


My guess is that its been installed incorrectly and that the hot water feed to the shower has been installed at the top of the tank rather than at the bottom. (eg. the tank has to refill up to a certain level in order for water to come out of the shower head?)
This makes NO sense in plumbing terms.

Did the plumber turn off the mains stopcock at all?? Has he opened it again fully???

BTW If the hot flow is poor it might be worth turning off the supply to the cylinder(the pipe that goes in the bottom) and remove the fitting from the top of the cylinder (you may lose a little water, have a big towel ready) and check how much hole there is left. In many areas scale can reduce a 22mm hole in this fitting down to around 3-4 mm!!! Yes, really.



There are also potential air-locking problems which could cause it. Is there pipework coming out of the TOP of the pump which then goes DOWNWARDS before reaching the shower?? Or pipework that dips BEFORE reaching the pump??

police state

4,385 posts

251 months

Friday 31st March 2006
quotequote all
Speaking of Power Showers...

What is a Power Shower?, is the 'power' reference to how fast the water is sprayed out?, or does it relate to the ability to feed water upstairs where gravity is not available?. The reason I ask is because I was thinking of having a shower installed at a flat, but as it's on the top floor(of 3), and the main feed is 'communal' and below the flat, a friend said that it is not worth putting a shower in becuase the water pressure would not be great enough to run through the shower. It sounds right, but how do the bath and kitchen sink manage to run 'a fast tap'?...

ferg

15,242 posts

288 months

Friday 31st March 2006
quotequote all
'Power' means it's pumped. You need STORED water before you can pump it which not many flats have in any quantity if at all. 'Combi' boilers for example cannot accomodate a pumped shower, but few need one anyway since the water is at an acceptable pressure already. You can pump stored wter upstairs with a shower pump but you need a 'negative head kit' essentially a button that short circuits the pump flow switch to get it moving when the FS takes over.

simpo two

93,160 posts

296 months

Friday 31st March 2006
quotequote all
ferg said:
I would suspect the ballvalve in the roof tank is not keeping up with the water being pumped out of the bottom. Fit a new one for 4 or 5 quid.

Possibly scaled up? My old cistern (before I replaced it with a sexy Grohe push-button jobbie) took about an hour to fill, drip by drip! Damn I enjoyed hurling it into a skip

police state

4,385 posts

251 months

Friday 31st March 2006
quotequote all
ferg said:
'Power' means it's pumped. You need STORED water before you can pump it which not many flats have in any quantity if at all. 'Combi' boilers for example cannot accomodate a pumped shower, but few need one anyway since the water is at an acceptable pressure already. You can pump stored wter upstairs with a shower pump but you need a 'negative head kit' essentially a button that short circuits the pump flow switch to get it moving when the FS takes over.


It doesn't have a combi boiler, or any boiler, except a ruddy great huge, nee massive thing in the basement of the block that as i understand it, feeds the flats their water, including communal central heating. If i turn the stopcock open to full, I can get the kitchen sink tap to spout like niagra falls at full chat; even the hot tap gushes; this seems to suggest that I 'have pressure', and do want to put a proper full monty powerful shower in. Bearing in mind no boiler/or tank in the flat. What's the answer?, and if there is one, what sort of cost do you think I would be be looking at?


ferg

15,242 posts

288 months

Friday 31st March 2006
quotequote all
You've got decent hot and cold pressure by the sounds of it, but it would be a good idea to measure it to check the balance. If they are the same you should be able to fit any modern mixer shower. Cost of shower??? £150 up wards. Fitting?? No idea without seeing it!!!

police state

4,385 posts

251 months

Friday 31st March 2006
quotequote all
ferg said:
You've got decent hot and cold pressure by the sounds of it, but it would be a good idea to measure it to check the balance. If they are the same you should be able to fit any modern mixer shower. Cost of shower??? £150 up wards. Fitting?? No idea without seeing it!!!


Thanks for the input Ferg.

pmanson

Original Poster:

13,391 posts

284 months

Saturday 1st April 2006
quotequote all
ferg said:
This makes NO sense in plumbing terms.

Thats why i'm not a plumber

ferg said:

Did the plumber turn off the mains stopcock at all?? Has he opened it again fully???


I'm not sure tbh, the shower was fitted a long time ago, but i've been at uni so its not been affecting me (until now that is)

ferg said:

BTW If the hot flow is poor it might be worth turning off the supply to the cylinder(the pipe that goes in the bottom) and remove the fitting from the top of the cylinder (you may lose a little water, have a big towel ready) and check how much hole there is left. In many areas scale can reduce a 22mm hole in this fitting down to around 3-4 mm!!! Yes, really.


That sounds easy enough to check (apart from having to dismantle the airing cupboard!

I assume its easy enough to clean?

ferg said:

There are also potential air-locking problems which could cause it. Is there pipework coming out of the TOP of the pump which then goes DOWNWARDS before reaching the shower?? Or pipework that dips BEFORE reaching the pump??


All the pipework is the same as the old shower (although it is fitted slightly lower on the wall than the old one (you can see the old mounting hole in the tiles)

ferg

15,242 posts

288 months

Saturday 1st April 2006
quotequote all
pmanson said:
ferg said:

BTW If the hot flow is poor it might be worth turning off the supply to the cylinder(the pipe that goes in the bottom) and remove the fitting from the top of the cylinder (you may lose a little water, have a big towel ready) and check how much hole there is left. In many areas scale can reduce a 22mm hole in this fitting down to around 3-4 mm!!! Yes, really.


That sounds easy enough to check (apart from having to dismantle the airing cupboard!

I assume its easy enough to clean?
If that fitting is scaled up it can be cleaned just by hacking the scale off with an old screwdriver. You might want to put it in some de-scaler and shine it up on the inside to finish... it helps stop it sticking again. Bear in mind that the 'gatevalve' used to isolate the cylinder (Red wheel handled thing) is a metal/metal seal and so the water MAY continue to trickle out of the cylinder so you may be on a timer!!!! You could put a cork in the inside of the tank connector in the storage tank in the roof if you can be bothered. Otherwise just legislate for lots of soaking up!!! You will need PTFE tape to put the fitting back.
pmanson said:

ferg said:

There are also potential air-locking problems which could cause it. Is there pipework coming out of the TOP of the pump which then goes DOWNWARDS before reaching the shower?? Or pipework that dips BEFORE reaching the pump??


All the pipework is the same as the old shower (although it is fitted slightly lower on the wall than the old one (you can see the old mounting hole in the tiles)
Check the run of the pipework. There may be high points with airvents on which could do with venting. If the roof tank HAS been running out (see first possible reason in my initial diagnosis) then it may have drawn air into the pump and it can't escape. A decent installation will hopefully have avoided any high points.


I still think the crap ballvalve in the roof tank is favourite.

JimNoble

410 posts

313 months

Saturday 1st April 2006
quotequote all
pmanson said:
Evening All,
Quick question for the PH Plumbers we have an Aqualisa Power Shower at home which doesn't work correctly. It was a replacement for another Aqualisa shower which died after many years of abuse!
When you first start having a shower its fine but water soon stops flowing, i'm then left standing in the freezing cold waiting for the water to reappear (after 30-60secs to a minute it does return). The pump is still making a noise even when there is no water flowing.
My guess is that its been installed incorrectly and that the hot water feed to the shower has been installed at the top of the tank rather than at the bottom. (eg. the tank has to refill up to a certain level in order for water to come out of the shower head?)
I have heard that there is 2 feeds to the shower (which may or not be correct?) is it just a case that these feeds are round the wrong way and that I can just swap them over? We never had this problem with the old shower which was in the same position as the current one.


A lot of power showers and thermostatic mixers have a feature where by if the cold water flow drops below a certain rate the shower will stop flowing. This is to ensure that you don't scald yourself by showering in hot water straight from the cylinder!

Sounds very much like you could be running out of cold water there. How big is your cold water storage tank? (*) Anything less than 25 gallons/114 litres and you could be running out of cold water after just a few minutes (what's the litres/minute rating of your power shower...). Perhaps your new shower is pumping water at a higher rate than the old one, and you're now running out of cold water where you weren't before.

(*) 1 cubic metre == 1000 litres. ie. a tank 0.5m x 0.5m x 0.5m would contain 125 litres when absolutely full.

The hot water always leaves the cylinder from the top, where the hottest water is. The cold water enters the bottom of the cylinder, gravity fed from the cold water storage tank. (If it looks like you have a pipe coming into the top of the cylinder from the tank in the loft, it's probably just a vent pipe).

The two feeds to your power shower are the hot and cold water. Hot from the cylinder, and cold from the storage tank. A power shower should have its own cold water feed, direct from the tank in the loft.

pmanson said:

Second question.......
We live in the Chilterns and the water is full of chalk so after a while everything starts to clog up. Is there anything we can flush the pipes out with? The hot water tap on the bath is obviously suffering having been installed 10 years ago so it takes forever to run a bath!


The bath will obviously flow a lot slower than the shower, because you only have gravity to rely on to get the water from the cylinder/tank to the tap. Could just be that.

You could fit an ion-exchange water softener (the type that needs filling with salt regularly). That would help reduce scale build up, but you can't use it for drinking water...

Jim

JimNoble

410 posts

313 months

Saturday 1st April 2006
quotequote all
police state said:
ferg said:
'Power' means it's pumped. You need STORED water before you can pump it which not many flats have in any quantity if at all. 'Combi' boilers for example cannot accomodate a pumped shower, but few need one anyway since the water is at an acceptable pressure already. You can pump stored wter upstairs with a shower pump but you need a 'negative head kit' essentially a button that short circuits the pump flow switch to get it moving when the FS takes over.

It doesn't have a combi boiler, or any boiler, except a ruddy great huge, nee massive thing in the basement of the block that as i understand it, feeds the flats their water, including communal central heating. If i turn the stopcock open to full, I can get the kitchen sink tap to spout like niagra falls at full chat; even the hot tap gushes; this seems to suggest that I 'have pressure', and do want to put a proper full monty powerful shower in. Bearing in mind no boiler/or tank in the flat. What's the answer?, and if there is one, what sort of cost do you think I would be be looking at?


Sounds like you may have a mains pressure hot water system there. In which case you want a thermostatic mixer shower connected to your hot water and mains cold water (not from a storage tank, although it sounds like you might not have one anyway). Wouldn't hurt to get one with a built in Pressure Balancing Valve as it gives the thermostatic mixer an easier time of keeping a stable temperature - depending on how generous the developer was with the hot/cold feed pipes! (Mine doesn't have one, and as there is only a ~15mm incoming cold water supply, the mixer struggles to cope if someone flushes a loo when you're in there...)

£150 sounds about right for a mixer and shower bits, as Ferg suggested. Screwfix probably have cheaper ones. There's some nice blingy push button start/stop digital ones on ebay for about 2-3x that though

Jim

ferg

15,242 posts

288 months

Saturday 1st April 2006
quotequote all
JimNoble said:

Sounds like you may have a mains pressure hot water system there. Jim
Beware the misnomer!

'Unvented Hot Water' rather than 'mains pressure' the hot will really only be at mains pressure if the mains pressure is really grim!!!!

jas xjr

11,309 posts

270 months

Saturday 1st April 2006
quotequote all
might be a problem with the pump. i will do most of my plumbing,apart from gas,but always get someone who knows what they are doing when it comes to pumps,very tricky in my ,limited experience.

denisb

509 posts

286 months

Saturday 1st April 2006
quotequote all
I had a similar problem.

This was caused by just about every single bend and valve getting blocked with chipboard chips. This also extended to the two filters in the pump unit.

Might be worth checking the pump supply flow rate over several minutes.

The chipboard got in the system because some prat used it to cover the cold water tank. Clearly they didn't know what hydroscopic meant!

JimNoble

410 posts

313 months

Sunday 2nd April 2006
quotequote all
ferg said:
JimNoble said:

Sounds like you may have a mains pressure hot water system there. Jim
Beware the misnomer!

'Unvented Hot Water' rather than 'mains pressure' the hot will really only be at mains pressure if the mains pressure is really grim!!!!


Not necessarily. AIUI quite a lot of communal heating/hot water systems these days use a heatbank/thermal store. The incoming [cold] mains is heated by passing it through a plate heat exchanger, extracting heat from the stored hot water as it goes. The pressure loss is minimal.

Jim

ferg

15,242 posts

288 months

Sunday 2nd April 2006
quotequote all
I stand corrected. I've never come across one that didn't use a PRV on the mains inlet.