A plumbing question - would this work?
A plumbing question - would this work?
Author
Discussion

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
We have 3 showers all with independent pipe runs fed from a hot water cylinder and a header tank in the loft but the pipe runs are long and therefore the system lacks pressure.

Just a little more pressure would make it more acceptable.

I know to fit a pump is the long term answer but for the moment I'm considering putting an expanded polystyrene 3" thick sheet in the tank to fit exactly inside the tank to float on the surface and then sit weights on top to give downward force and act like a piston. I'll leave a few small holes in the sheet for the fresh water entering the header tank to eventually equalize and the styrene to float.

Does that sound like it will work?

rsvmilly

11,288 posts

270 months

Friday 8th September 2006
quotequote all
No.

Better to just raise the tank in the loft

B17NNS

18,506 posts

276 months

Friday 8th September 2006
quotequote all
surely it needs putting on a conveyor belt of some description?

victormeldrew

8,293 posts

306 months

Friday 8th September 2006
quotequote all
Kentish said:
We have 3 showers all with independent pipe runs fed from a hot water cylinder and a header tank in the loft but the pipe runs are long and therefore the system lacks pressure.

Just a little more pressure would make it more acceptable.

I know to fit a pump is the long term answer but for the moment I'm considering putting an expanded polystyrene 3" thick sheet in the tank to fit exactly inside the tank to float on the surface and then sit weights on top to give downward force and act like a piston. I'll leave a few small holes in the sheet for the fresh water entering the header tank to eventually equalize and the styrene to float.

Does that sound like it will work?
No. You really think the "pressurised" water will choose not to exit via the few small holes?

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
rsvmilly said:
No.

Better to just raise the tank in the loft


I'd need to extend all the pipes and this is as much work as fitting a manifold and big pump

I may be able to raise it an inch or two but I doubt that will give much better head of pressure?

victormeldrew

8,293 posts

306 months

Friday 8th September 2006
quotequote all
B17NNS said:
surely it needs putting on a conveyor belt of some description?
I was going to ask about planes and conveyors, but though that might be taking the pee a little!

Bee_Jay

2,599 posts

277 months

Friday 8th September 2006
quotequote all
No - will not work.

Any piston that tries to 'increase pressure' in such a way would need to be 'water-tight' and you drilling holes in it would defeat the purpose!

Either raise the tank, use pumps (you can get self contained hot/cold feed thermostatic showers now that run off 3A and are very easy to fit) or consider fitting a 'megaflow' pressurised system. Or replace the piping to the showers with 22mm instead of 15mm.

Many ways to solve this, but a bit of polystyrene with weights on and holes in will not work and will just sink.

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
victormeldrew said:
Kentish said:
We have 3 showers all with independent pipe runs fed from a hot water cylinder and a header tank in the loft but the pipe runs are long and therefore the system lacks pressure.

Just a little more pressure would make it more acceptable.

I know to fit a pump is the long term answer but for the moment I'm considering putting an expanded polystyrene 3" thick sheet in the tank to fit exactly inside the tank to float on the surface and then sit weights on top to give downward force and act like a piston. I'll leave a few small holes in the sheet for the fresh water entering the header tank to eventually equalize and the styrene to float.

Does that sound like it will work?
No. You really think the "pressurised" water will choose not to exit via the few small holes?


Not if the smaller holes are less than the area of the pipework orifices.
The small holes may not even be required if the styrene doesn't fit tight to the sides of the tank. Water will always take the easier route and as long as there is no larger escape route for it then the main one will be the pipes to the showers.

esselte

14,626 posts

296 months

Friday 8th September 2006
quotequote all
Kentish said:
We have 3 showers all with independent pipe runs fed from a hot water cylinder and a header tank in the loft but the pipe runs are long and therefore the system lacks pressure.



Shirley it's not the length of the pipe runs that reduce the pressure but the head of the system?If you could raise this than that would increase the water pressure.

alfaman

6,416 posts

263 months

Friday 8th September 2006
quotequote all
You havent studied Engineering or Physics ..... have you ?


Increase the hydrostatic head by making the tank about 1 metre deeper.... just gaffer tape some boarding around the tank , seal the gap between boards and tank with some bath sealant ...... and hey-presto , a deeper tank thumbup

Guaranteed it wont leak if you apply the tape carefully.

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
In theory, whatever weight you place on top will be your increase in head of pressure as long as that weight isn't great enough to sink the styrene then (in theory) it should work.

The assumption is also made that the styrene is a very close fit to the tank walls so that the easiest route for water to escape will be down the pipe.

It's a round tank BTW (not that it makes any difference).

Bee_Jay

2,599 posts

277 months

Friday 8th September 2006
quotequote all
esselte said:
Kentish said:
We have 3 showers all with independent pipe runs fed from a hot water cylinder and a header tank in the loft but the pipe runs are long and therefore the system lacks pressure.



Shirley it's not the length of the pipe runs that reduce the pressure but the head of the system?If you could raise this than that would increase the water pressure.


As water flows through a pipe it loses pressure due to 'friction loss', the length does matter. Hence me saying use 22mm instead of 15mm - less friction loss.

victormeldrew

8,293 posts

306 months

Friday 8th September 2006
quotequote all
Trying to be helpful however ...

The length of the pipe runs will have little effect on pressure. A larger tank might - which would be similar to raising the existing one. Fit a second tank and run some of the outlets from that?

Bee_Jay

2,599 posts

277 months

Friday 8th September 2006
quotequote all
anonymous said:
[redacted]


yes

victormeldrew

8,293 posts

306 months

Friday 8th September 2006
quotequote all
anonymous said:
[redacted]
Yes, a principle known as "sinking" in the nautical world I believe!

alfaman

6,416 posts

263 months

Friday 8th September 2006
quotequote all
Kentish said:
In theory, whatever weight you place on top will be your increase in head of pressure as long as that weight isn't great enough to sink the styrene then (in theory) it should work.

The assumption is also made that the styrene is a very close fit to the tank walls so that the easiest route for water to escape will be down the pipe.

It's a round tank BTW (not that it makes any difference).


rofl The ONLY thing increasing the pressure in the tank will be the water depth

Bee_Jay

2,599 posts

277 months

Friday 8th September 2006
quotequote all
victormeldrew said:
Trying to be helpful however ...

The length of the pipe runs will have little effect on pressure. A larger tank might - which would be similar to raising the existing one. Fit a second tank and run some of the outlets from that?



The length of pipe DEFINITELY has an effect on pressure: www.diydata.com/planning/ch_design/pressuredrop.htm

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
anonymous said:
[redacted]


yes


That depends on the natural bouyancy of the polystyrene sheet and how much weight is above it.

I'm pretty certain it will work to some extent but dependent on getting the diameter of the sheet correct and the weights above it and the even distribution of that weight.

I'll do some math when I get home too see whether it is feasible. I'm an ex-hydraulics design engineer so I'm quietly confident

Kentish

Original Poster:

15,169 posts

263 months

Friday 8th September 2006
quotequote all
anonymous said:
[redacted]


Go play with the buses!

Bee_Jay

2,599 posts

277 months

Friday 8th September 2006
quotequote all
Kentish said:


That depends on the natural bouyancy of the polystyrene sheet and how much weight is above it.

I'm pretty certain it will work to some extent but dependent on getting the diameter of the sheet correct and the weights above it and the even distribution of that weight.

I'll do some math when I get home too see whether it is feasible. I'm an ex-hydraulics design engineer so I'm quietly confident


But surely all you would be doing is getting the sheet neutrally bouyant and cancelling the effect. i.e. more bouyant the sheet is, more weight you can put on it, however the resultant downward force would not change.

As long as there is somewhere else for the water to go (i.e. up through the sheet) it is pointless.