Really dumb central heating question
Discussion
If I turn the heating on but some of the radiators are turned off will my gas bill be less than if all of the radiators are turned on? Do I burn just as much gas because the boiler uses the same amount of gas regardless of how many radiators are 'accepting' heat, or will the boiler use less gas as less radiators are demanding a supply of heat?
There is a thermostat in the boiler. If less rads are in use the return temp will be higher and the boiler will be firing up less as a result therefore you will use less gas.
Edit: Boiler and thermostat arse about face! (I don't think anyone noticed though!)
Edit: Boiler and thermostat arse about face! (I don't think anyone noticed though!)
Edited by Ganglandboss on Sunday 31st August 22:05
King Herald said:
Ganglandboss said:
There is a boiler in the thermostat. If less rads are in use the return temp will be higher and the boiler will be firing up less as a result therefore you will use less gas.
We have no boiler in our thermostat, as it is tiny.
t - wrong way round! 
speedychrissie said:
it does ofcourse depend on your system, but for me it would cost a lot less. if i turn off a radiator then the water just bypasses it and my boiler just maintains a constant output temperature. so if there is less water circulating, less gas will be used.
Depends on where the rads are. The ones still on my stay on longer until the thermostat turns off...Shutting off rooms - no rads, doors shut, you'd save gas,
King Herald said:
Ganglandboss said:
There is a boiler in the thermostat. If less rads are in use the return temp will be higher and the boiler will be firing up less as a result therefore you will use less gas.
We have no boiler in our thermostat, as it is tiny. It is there as a fudge around cheap-arse s
t design. Instead of making the thermostat element with a usefully low hysteresis, they make it with a massive hysteresis and then heat the bloody thing when it's "on" to bias it and fake a low hysteresis. They give it the fancy name of "anticipator" to camouflage its being a bodge for s
tty design and to shut up the people who keep wondering what this 100k resistor is for.Pigeon said:
You probably have a heater in it, though.
It is there as a fudge around cheap-arse s
t design. Instead of making the thermostat element with a usefully low hysteresis, they make it with a massive hysteresis and then heat the bloody thing when it's "on" to bias it and fake a low hysteresis. They give it the fancy name of "anticipator" to camouflage its being a bodge for s
tty design and to shut up the people who keep wondering what this 100k resistor is for.
You know what, the second I saw that 100k resistor in my thermostat I thought; someone has made a $hitty design here, and they're using this resistor to camouflage it. It is there as a fudge around cheap-arse s
t design. Instead of making the thermostat element with a usefully low hysteresis, they make it with a massive hysteresis and then heat the bloody thing when it's "on" to bias it and fake a low hysteresis. They give it the fancy name of "anticipator" to camouflage its being a bodge for s
tty design and to shut up the people who keep wondering what this 100k resistor is for.Good job not all of us are so easily decieved, eh?

Pigeon said:
It is there as a fudge around cheap-arse s
t design. Instead of making the thermostat element with a usefully low hysteresis, they make it with a massive hysteresis and then heat the bloody thing when it's "on" to bias it and fake a low hysteresis. They give it the fancy name of "anticipator" to camouflage its being a bodge for s
tty design and to shut up the people who keep wondering what this 100k resistor is for.
Leave it!
t design. Instead of making the thermostat element with a usefully low hysteresis, they make it with a massive hysteresis and then heat the bloody thing when it's "on" to bias it and fake a low hysteresis. They give it the fancy name of "anticipator" to camouflage its being a bodge for s
tty design and to shut up the people who keep wondering what this 100k resistor is for.
Pig your either a snob when it comes to the KISS approach to engineering, you enjoy your water system to be "just so" or you *really* care about saving a few pence on your power bill
. Mind you now that you mention it...
Gassing Station | The Pie & Piston Archive | Top of Page | What's New | My Stuff