Heating engineer help?
Author
Discussion

Mtnboarder

Original Poster:

29 posts

228 months

Saturday 8th November 2008
quotequote all
Can anyone help with my heating problem- I've got white meter through Hydro-Electric and the overnight hot water hasn't worked for a while, although the manual boost is fine. As these are separate elements in the tank I left it until last week when the plumber was fitting a new bathroom and got it changed while he was here. Still no joy though.
The only other component of the system is the control unit- this was changed in April when a new kitchen was installed so is unlikely to be the problem. Any ideas? The storage heaters work so the signal into the meter seems to be ok.

ferg

15,242 posts

287 months

Saturday 8th November 2008
quotequote all
Does the new element have a manual reset hi-limit stat?? If so it may need resetting. Push the tiny little button in the centre of the stat. (Not the big rod-stat like elements have always had)