Parents' Double Glazing
Parents' Double Glazing
Author
Discussion

bleesh

Original Poster:

1,112 posts

283 months

Wednesday 10th December 2008
quotequote all
Mum and Dad had some UPVC double glazing installed last year, made by a local company (in Aldershot, Hampshire) and this replaced the original single glazed windows (wooden frames) and secondary glazing in aluminium frames.

Dad is convinced that the house is both colder and noisier NOW than it was with the previous setup, to the extent that he wants to get secondary glazing installed inside the double glazing...... rolleyes

A couple of general questions...
a) is there a regulation that says how big the gap between the panes should be, and if so what is that gap?,
b) is the gap a vacuum, or air, or other gas?
c) it it likely the UPVC conducts cold in/heat out more than the original wood?

Appreciate any answers/info,

Cheers people,

Steve

hobbiniho

109 posts

220 months

Wednesday 10th December 2008
quotequote all
how reputable is the company that installed them??? could possibly be shody instalation and they may not be propperly sealed into the house, what is the house built out of??

Bob Loblaw

466 posts

234 months

Wednesday 10th December 2008
quotequote all
The space between the panes is just air. For the least thermal loss the space should be 15-20mm

Deva Link

26,934 posts

274 months

Wednesday 10th December 2008
quotequote all
I can well imagine they're noisier - IIRC the optimal gap for noise suppression is several inches rather than a few mm (typically 16) of uPVC sealed units.

Our house has uPVC windows put in about 20years ago and the mechanical fit of the openers really isn't very good so noise comes through there.

Wings

5,967 posts

244 months

Wednesday 10th December 2008
quotequote all
Standard double glazing does not give much benefit in sound proofing, although the wider apart the panes of glass are, the greater the benefit for sound proofing is achieved.

Standard double glazing does not give much benefit in sound proofing, although
the wider apart the panes of glass are, the greater the benefit for sound proofing is achieved.

Placing a coin/object against the glass of the double glazed unit, and measuring the distance of the reflections,will determine the distance between each pane of the double glazed unit.


Simond001

4,519 posts

306 months

Wednesday 10th December 2008
quotequote all
the house probably is colder and noisier. Well fitted secondary glazing offers a larger "air gap" between the panes, so is able to cope with the two temperature variables better and keeps the noise further away.

Simond001

4,519 posts

306 months

Wednesday 10th December 2008
quotequote all
most modern sealed units are 20mm air gap. Older stuff often 12mm gap.

V8 Animal

6,015 posts

239 months

Wednesday 10th December 2008
quotequote all
bleesh said:
Mum and Dad had some UPVC double glazing installed last year, made by a local company (in Aldershot, Hampshire) and this replaced the original single glazed windows (wooden frames) and secondary glazing in aluminium frames.

Dad is convinced that the house is both colder and noisier NOW than it was with the previous setup, to the extent that he wants to get secondary glazing installed inside the double glazing...... rolleyes

A couple of general questions...
a) is there a regulation that says how big the gap between the panes should be, and if so what is that gap?,
b) is the gap a vacuum, or air, or other gas?
c) it it likely the UPVC conducts cold in/heat out more than the original wood?

Appreciate any answers/info,

Cheers people,

Steve
16mm gap is the minimum gap as regulations stand today coupled with k glass in pvc windows.
The gap is air but could be filled with argon but i doubt it tell tell sign is angled plug in a corner of the inside of the unit.
Secondary glazing is very good for noise insulation the bigger gap between the window and the secondary is better.
Your dad is most probably correct in his assumption not so sure about heat loss though.
The better upvc windows have barriers in the section for heat loss yours may well be the cheaper section.
V8 Animal

Pickled Piper

6,452 posts

264 months

Wednesday 10th December 2008
quotequote all
I have just installed some secondary double glazing panels on some old windows that were too nice to pull out and replace. I can categorically tell you the noise and heat insulation is better than for the conventional double glazed units that we have in the other parts of the house. I think it is primarily down to he large air gap and because the secondary glazing is 4mm thick fixed panels, so less seals for the air to leak through.

pp

Deva Link

26,934 posts

274 months

Wednesday 10th December 2008
quotequote all
Simond001 said:
most modern sealed units are 20mm air gap. Older stuff often 12mm gap.
I went for the middle number to save boring detail.

Busamav

2,954 posts

237 months

Wednesday 10th December 2008
quotequote all
16 mm gap and it should be filled with argon .

I would be checking the fit and making sure there is a perimeter mastic seal both internal and externally

If there has been a bad measure of the units , there could be a lot of foam and mastic doing a job it wasnt designed for .

I would call the installer back for a look.

Have they got the Fensa certificates ?

If you dont get any satisafaction with the installer , have a word with Building control , FENSA companies self certify their work , and a very high percentage of those checked out do not meet the set standard .