Xpelair fan - help required
Discussion
Hi all,
Does anyone have any experience of Xpelair bathroom\shower fans? In particular the XIM100+T model.
I've got one I'm trying to install but the labels for the connectors don't match the instructions!!
On the fan I've got labelled
T (Black wire)
L2(Blue wire)
L1(Grey wire)
N (Brown wire)
Some how the instructions don't have this exact model, nore does the Xpelair website, but both of them have the following wire spec...
T (Black wire)
N2(Blue wire)
N1(Grey wire)
L (Brown wire)
Anyone know which is right? The techincal helpline is closed at weekends!!
Thanks,
Tescor
Does anyone have any experience of Xpelair bathroom\shower fans? In particular the XIM100+T model.
I've got one I'm trying to install but the labels for the connectors don't match the instructions!!
On the fan I've got labelled
T (Black wire)
L2(Blue wire)
L1(Grey wire)
N (Brown wire)
Some how the instructions don't have this exact model, nore does the Xpelair website, but both of them have the following wire spec...
T (Black wire)
N2(Blue wire)
N1(Grey wire)
L (Brown wire)
Anyone know which is right? The techincal helpline is closed at weekends!!
Thanks,
Tescor
cupra20vt said:
i would guess going by the colours of the cables (as an electrician)
T (Black wire)
N2(Blue wire)
N1(Grey wire)
L (Brown wire)
T= timer- perminant feed to run on running timer.
N2= neutral
N1= neutral link
L= switch wire (live)
If the above does not work try swapping the "T" termination with the "L" as sometimes the terminals are called T= Trigger / Switch Wire (to trigger the timer function) and L as the permanent Live. Either way the N1 & N2 are a looped Neutral.T (Black wire)
N2(Blue wire)
N1(Grey wire)
L (Brown wire)
T= timer- perminant feed to run on running timer.
N2= neutral
N1= neutral link
L= switch wire (live)
HTH