removing the lower part of a chimney ! ?
removing the lower part of a chimney ! ?
Author
Discussion

unclemark123

Original Poster:

883 posts

237 months

Monday 16th February 2009
quotequote all
right, i have an internal chimney running all the way up through my house and out the top of the roof.
it is no longer used.

on the ground floor i would like to taper the chimney off back into the wall at 45 degrees.

is this possible ? according to my architect tonight it is ?

mark smile

darronwall

1,730 posts

225 months

Monday 16th February 2009
quotequote all
anythings possible,just use a competant builder

V12Les

3,985 posts

225 months

Monday 16th February 2009
quotequote all
As long as its bonded into the wall then yes it can be done...by a competent builder.

BiggusLaddus

821 posts

260 months

Monday 16th February 2009
quotequote all
You can't taper it down at 45deg, but you can remove it completely. You can't have a chimney above without it being supported below.

The best way would be to put a beam to support the chimney breast hidden within the depth of the first floor. If you were removing the chimney all the way up to the loft then you could use 'gallows' brackets to take the weight of the chimney back to the wall.

Gunny Sergeant D

2,248 posts

269 months

Tuesday 17th February 2009
quotequote all
I had this done on a previous property. A quote nicked from the Internet and a pic. "you need to use a pre-stressed lintel and then support it with gallows brackets (of a height at least 1.5 times projection)...."