radiator fan blew its 25amp fuse.....why guys??
radiator fan blew its 25amp fuse.....why guys??
Author
Discussion

K-Serious

Original Poster:

52 posts

299 months

Monday 31st January 2005
quotequote all
got an S2. Happened when idling in traffic jam in city...have only gone over 100C twice before in last 6 month but could hear fan kicking in. this time though the temp went to 111C and no fan noise!!!! have replaced with 20 amp fuse halfords dont do 25s! think ill go and kick the dealers ass

Martin_S

9,939 posts

275 months

Monday 31st January 2005
quotequote all
Couldn't say for sure but it might be worth checking that the fan isn't starting to seize.

This is a common problem with Elises, since when standing in the rain water can run straight down through the horizontal radiator and onto the fan. And, of course, the fan cuts in fairly infrequently (particularly at this time of year), so easy for things to seize up.

I assume that if it did start to seize, the motor might be drawing sufficient current in its efforts to turn the fan that it would blow a fuse?

weed

211 posts

271 months

Tuesday 1st February 2005
quotequote all
If the Fan is failing it will draw more current.
So if the 20A fuse lasts a bit before blowing, the fan is knackered.
If the fuse blows right away then the power wire to the fan is shorting to earth.
m

K-Serious

Original Poster:

52 posts

299 months

Thursday 3rd February 2005
quotequote all
havent properly looked, pretty mech minded but what would it take to chech the fan (access it)?



cheers guys

Steff

1,421 posts

293 months

Thursday 3rd February 2005
quotequote all
You may have to remove the front clam to remove the rad to get at the fan....

Martin_S

9,939 posts

275 months

Thursday 3rd February 2005
quotequote all
To check the fan on the S1 there are two basic tests that might help:

1) Remove the relay and bridge the terminals on the socket with a bit of wire. If you have current, you should get a nice little blue spark as the wire makes contact. The fan should turn on...if you get the spark but no action from the fan, then it is most likely seized. No blue spark most likely indicates a break or bad connection on the wiring.
If it runs, but is reluctant or slows down very quickly when you remove the current, then it is partially siezed - in good condition it should start instantly and spin down quite slowly (several seconds to stop).

2) Remove the front intake grille (two crosshead screws, then lift the grille up and out - two wire 'pegs' locate in holes in the bodyshell on a standard S1). Reach in under the radiator and you should be able to get your fingers to the fan blades and spin it over by hand. If it is at all stiff, then it has seized.

Unfortunately, to replace the fan is definitely a clamshell-off job. Count on a day's work, including buggering about with the stupid rubber 'rivnuts' that Lotus use to fix the clam, and which always just turn 'cos the screws have rusted into them!

K-Serious

Original Poster:

52 posts

299 months

Sunday 6th February 2005
quotequote all
is it possible to check the fan on an S2 by removing front under tray?

cheers guys

Martin_S

9,939 posts

275 months

Sunday 6th February 2005
quotequote all
K-Serious said:
is it possible to check the fan on an S2 by removing front under tray?

cheers guys


No, 'fraid not.

The radiator is mounted on top of a moulding assembly that doubles as radiator ducting and front deformable crash structure. Removing the front undertray will just give you a nice, clear view of the bottom of this moulding.