Heater fan
Author
Discussion

enjybenjy

Original Poster:

928 posts

284 months

Wednesday 15th November 2006
quotequote all
My heater fan has stopped working. Apparently I have the HVAC 'all in one' unit, which is ed. This'll cost £360 for the parts plus labour. I think that is discusting for what is, a fan with a resitor matrix. Anyone know of a spare one for sale?

Very, very pissed off.

Paul RN

1,168 posts

245 months

Wednesday 15th November 2006
quotequote all
HVAC is the Heading Ventilation and Air Conditioning system. Does your car have air-con?

enjybenjy

Original Poster:

928 posts

284 months

Wednesday 15th November 2006
quotequote all
Yep. Lost fan speed 1 and 2, now lost all 3. The unit is a one piece (so all the resitors are internal). I can't believe that to replace this is going to cost SERIOUS money. Can someone shed light on this? It must be repairable or what?!?!

dgr

289 posts

265 months

Wednesday 15th November 2006
quotequote all
The Blower motor unit with the resistor pack is 160 quid. The bad news is that to replace it the front clam needs come off. Westover's charged me 727 pounds to do mine recently. It would of course cost less at a specialist as the labour rate is lower.

Nearly bought a new one as an alternative, however the man maths were spotted at home!

Paul RN

1,168 posts

245 months

Wednesday 15th November 2006
quotequote all

enjybenjy

Original Poster:

928 posts

284 months

Wednesday 15th November 2006
quotequote all
Ta. Clam's already off as I hit some kind of animal/brick. Need a new clam basically. My main concern is the bloody expense just to sort this heater out. I find it hard to believe that lotus charge 300 odd quid for a blower unit. It must be a different unit to the £160 one. I trust my lotus mechanic, and he says there were about 3 different types. perhaps it's because I have AC as well...

dgr

289 posts

265 months

Wednesday 15th November 2006
quotequote all
Part number EB117P0025F if that helps. I was orignally quoted 300ish, but that was for a new heater unit vs just the blower. Mine is late 2002 and doesn't have Aircon. Well documented problem on here and SELOC.

enjybenjy

Original Poster:

928 posts

284 months

Wednesday 15th November 2006
quotequote all
Thanks for your help Dave.

sequential

70 posts

243 months

Wednesday 15th November 2006
quotequote all
I had a similar problem with mine - fan speed setting three packed up and front clam needed removal. Don't know details behind fix, but also had something to do with resistors in HVAC. Thankfully, it was covered under warranty, but condensation started forming on both front lighting units following fix - dealer told me TADTS. Rubbish IMO - it wasn't doing that before the clam was removed! I'm booking it back in to see what the dealer can do. I wonder whether a repair in an airconditioned environment would have stopped condensation forming?