ETA2824 Gaining 7 secs per minute !!
Discussion
The Automatic movement in my O&W M4 appears to have gone nuts. It's gaining around 7 secs every minute. I guess this isn't a case of a little adjustment. Anyone have an idea what might have gone wrong, I am looking at having Ryetime take a look, but just interested if anyone has any wisdom to share before I do.
RLK500 said:
Watch is 3 years old. Don't know how it would have become magnetised, wear it as my daily beater, have done nothing unusual or been anywhere different. Very strange.
Impossible to be sure of the cause without inspecting the watch but I am sure Rytetime will sort it out. If its worn daily it could well have been inadvertently magnetised or received a knock that jumped a hairspring coil over the regulating pin, or a good number of other possibilities for it suddenly starting to gain so much.
Mr_C said:
One of my seiko 7s36's gains about 15secs/day, can this be adjusted out?
That depends on if it is just badly adjusted or if there is some other underlying problem. On the face of it 15s/day is within the range of adjustment but that is assuming that there is no other problem.Tanguero said:
That depends on if it is just badly adjusted or if there is some other underlying problem. On the face of it 15s/day is within the range of adjustment but that is assuming that there is no other problem.
Thanks. At 5pm today I'll know exactly how far out it is. Looking like its about 10secs really. Can any local watch shop adjust it?Is it likely to settle down? It's only about a month old, but I don't really want to send it back to creation.
Mr_C said:
Thanks. At 5pm today I'll know exactly how far out it is. Looking like its about 10secs really. Can any local watch shop adjust it?
Is it likely to settle down? It's only about a month old, but I don't really want to send it back to creation.
If the rate does "settle down" then that is indicative of a more serious problem - the rate should be fairly constant in any given position. If the rate stays stable then it may be a matter of adjustment.Is it likely to settle down? It's only about a month old, but I don't really want to send it back to creation.
Seiko don't publish a rate range fro that movement, but 15 is just about within the acceptable range for that quality of movement. Anecdotally they can hold a rate of +-6 s/d if you have a goodun and it is well adjusted. But I would ask Creation what rate they would expect before assuming there is a problem and sending it back.
If an old style steel hairspring becomes magnetised, you tend to get two (or more) coils sticking together, which dramatically changes the rate. Given how fine the hairspring is and how close together the coils lie, it doesn't take very much magnetism to do that.
Obviously modern Invar, Elinvar and Nivarox springs are very much less sensitive to that problem, but a magnetised watch can misbehave for all sorts of reasons. Given that it is a 10 second job to demagnetise, its probably a good starting point.
Obviously modern Invar, Elinvar and Nivarox springs are very much less sensitive to that problem, but a magnetised watch can misbehave for all sorts of reasons. Given that it is a 10 second job to demagnetise, its probably a good starting point.
456GT said:
How much of a problem is magnetisation? How does this happen?
It's not a big problem, and can be cured in a few seconds if you've got a demagnetiser. It can happen if the watch is exposed to a magnetic field. An obvious one is a loudspeaker of some kind. I've learned the hard way that one of my watches particularly doesn't like being left next to the kitchen radio while I do the washing up...
Ev_ said:
456GT said:
How much of a problem is magnetisation? How does this happen?
It's not a big problem, and can be cured in a few seconds if you've got a demagnetiser. It can happen if the watch is exposed to a magnetic field. An obvious one is a loudspeaker of some kind. I've learned the hard way that one of my watches particularly doesn't like being left next to the kitchen radio while I do the washing up...
And to another poster - somebody typically in need of one would be a power station worker (that was the brief for the original Rolex Milgauss, I believe).
I've heard of people managing to demagnetise them by putting the watch beside a CRT TV screen and turning it off, and also using the guns in libraries and shops etc which deactivate the warning sensor things which prevent items being removed from the premises. However I have no idea of the success rate using these.....
You can get a perfectly serviceable watch demagnetiser for under a tenner on fleabay.
http://www.ebay.co.uk/sch/i.html?_trksid=p2050601....
http://www.ebay.co.uk/sch/i.html?_trksid=p2050601....
Tanguero said:
If the rate does "settle down" then that is indicative of a more serious problem - the rate should be fairly constant in any given position. If the rate stays stable then it may be a matter of adjustment.
Seiko don't publish a rate range fro that movement, but 15 is just about within the acceptable range for that quality of movement. Anecdotally they can hold a rate of +-6 s/d if you have a goodun and it is well adjusted. But I would ask Creation what rate they would expect before assuming there is a problem and sending it back.
Just checked at its actually +6 to 7 secs so not too bad...Seiko don't publish a rate range fro that movement, but 15 is just about within the acceptable range for that quality of movement. Anecdotally they can hold a rate of +-6 s/d if you have a goodun and it is well adjusted. But I would ask Creation what rate they would expect before assuming there is a problem and sending it back.