What type of switch is this?
What type of switch is this?
Author
Discussion

CC07 PEU

Original Poster:

2,492 posts

228 months

Monday 30th May 2011
quotequote all
I'd like to replace a faulty switch from my desk lamp and I don't know what type of switch I need to be searching for as a replacement.

The old switch is a rotational three way i.e. so that the two lamps can either be on one at a time, both can be on, or the lamp can be off.

The switch I extracted from the old lamp is pictured below but what should I be asking for?

It was riveted and I had to break it to get the wires out. It says on the switch 6A 125 VAC if that makes any difference. Any help appreciated:


miniman

29,411 posts

286 months

Monday 30th May 2011
quotequote all
I think the problem you'll have is that it's something that's much more common in the USA - most desk / table lamps, especially in hotels, seem to have them.

Here's something similar:

http://gb.mouser.com/ProductDetail/ALPS/SRBM131300...

I couldn't find an equivalent from the normal UK suppliers (RS / Farnell, Maplin etc.)

bimsb6

8,617 posts

245 months

Tuesday 31st May 2011
quotequote all
Wow that penny is huge !

minicab

8,182 posts

220 months

Tuesday 31st May 2011
quotequote all
It's a three position rotary switch.... 6A/125VAC is the rating.

This kind of thing - although this is a 2 position http://www.sourceresearch.com/Store1/quickstore.cf...

motco

17,394 posts

270 months

Tuesday 31st May 2011
quotequote all
Should you be using a switch rated at 125Vac on 230Vac? yikes

JM

3,170 posts

230 months

Tuesday 31st May 2011
quotequote all
motco said:
Should you be using a switch rated at 125Vac on 230Vac? yikes
It's more the amps and watts he'd need to worry about.


motco

17,394 posts

270 months

Tuesday 31st May 2011
quotequote all
JM said:
motco said:
Should you be using a switch rated at 125Vac on 230Vac? yikes
It's more the amps and watts he'd need to worry about.
So you wouldn't think that arcing gaps are less on 125Vac switches?

Simpo Two

91,526 posts

289 months

Tuesday 31st May 2011
quotequote all
Is 6A at 125V the same load as 3A at 250V?

Ganglandboss

8,501 posts

227 months

Tuesday 31st May 2011
quotequote all
Simpo Two said:
Is 6A at 125V the same load as 3A at 250V?
Both are 750W of power but the strain on the conductors will be greater at lower voltage because the current is higher. That is the reason extra low voltage lighting needs bigger cables and why power is distributed at high voltage.

hairyben

8,516 posts

207 months

Tuesday 31st May 2011
quotequote all
Ganglandboss said:
Both are 750W of power but the strain on the conductors will be greater at lower voltage because the current is higher. That is the reason extra low voltage lighting needs bigger cables and why power is distributed at high voltage.
Theoretically, a switch built for 250v will need to snap into place quicker to reduce arcing, which will be more of an issue at the higher voltage. In practice the biggest concern would be the standard of the insulation between live terminals and one's fingers will differ. You simply shouldn't use parts at higher than their rated insulation, in the same way you wouldn't inflate a tyre rated at max 50psi to 100psi.

For old parts like that you could try the hobbyist scene- people who like/restore old radio sets and suchlike junk? they must have forums, who might lead you to specialist suppliers?

miniman

29,411 posts

286 months

Tuesday 31st May 2011
quotequote all
hairyben said:
Theoretically, a switch built for 250v will need to snap into place quicker to reduce arcing, which will be more of an issue at the higher voltage. In practice the biggest concern would be the standard of the insulation between live terminals and one's fingers will differ. You simply shouldn't use parts at higher than their rated insulation, in the same way you wouldn't inflate a tyre rated at max 50psi to 100psi.

For old parts like that you could try the hobbyist scene- people who like/restore old radio sets and suchlike junk? they must have forums, who might lead you to specialist suppliers?
True, but at the voltages and currents we're talking about here it's not going to be critical. In fact, if you look at the link above, the switch in question is rated for both 115V and 230V with the appropriate change in current rating.