Underfloor heating expertise needed
Discussion
I m currently having some work done and looking into underfloor heating and it is a veritable minefield, and unfortunately the builder/spark doesn't know much other than how to fit it.
He recommends Warm-up because in his own admission its the 'one he knows'.
It also happens to be the most expensive.
He doesn't know whether it will be suitable for a prmary heat source in the kitchen or not.
He doesn't know whether it needs to be on thermal boards (eyewateringly expensive) or whether the much cheaper thermal matting is sufficient.
So assuming Im going to choose 200w powerfull heating,
1)is this sufficient to heat a ktichen with a galleried ceiling and bi-fold doors (through a limestone floor)
2)Is there much different between the brands or is it a homogeneous product which works as well as each other
3)Laying it on to screed/concrete-do I need thermal boards or is matting equally adequeate?
Many thanks
He recommends Warm-up because in his own admission its the 'one he knows'.
It also happens to be the most expensive.
He doesn't know whether it will be suitable for a prmary heat source in the kitchen or not.
He doesn't know whether it needs to be on thermal boards (eyewateringly expensive) or whether the much cheaper thermal matting is sufficient.
So assuming Im going to choose 200w powerfull heating,
1)is this sufficient to heat a ktichen with a galleried ceiling and bi-fold doors (through a limestone floor)
2)Is there much different between the brands or is it a homogeneous product which works as well as each other
3)Laying it on to screed/concrete-do I need thermal boards or is matting equally adequeate?
Many thanks
I'm just doing this at the moment. I'm not a fitter by trade, so I've have spoken to about half a dozen people, including fitters, suppliers, and end-users. It is not the sole heat source, and will be under 10mm ceramic tiles.
This is what I'm doing -
latex screed to level floor, then pva to seal.
flexible tile adhesive (Bostik OPF), then set 10mm marmox/wedi onto that.
then lay the cable (i've got 600watts for 7m of floor)and latex screed again to cover the wires. check the resistance readings as you go.
check the resistance readings again
Then pva again, and tile.
Oh, and use an intelligent controller that can self-learn start times to hit the temps that you need.
This is what I'm doing -
latex screed to level floor, then pva to seal.
flexible tile adhesive (Bostik OPF), then set 10mm marmox/wedi onto that.
then lay the cable (i've got 600watts for 7m of floor)and latex screed again to cover the wires. check the resistance readings as you go.
check the resistance readings again
Then pva again, and tile.
Oh, and use an intelligent controller that can self-learn start times to hit the temps that you need.
Is this a new build, extension or refurb?
If electric ufh is your only option then I would be insulating the floor below to the maximum to minimise heat loss. If you can't insulate then don't bother. The install will cost you a fortune to run and not work very well.
I would also ensure it covers the entire exposed floor area as the heat doesn't radiate between tiles well at all. Make sure you have sufficient controls fitted as well.
There is a member on here who runs an ufh company / supplier but I can't remember who it is.
Google will throw up a good number of websites to look through.
If electric ufh is your only option then I would be insulating the floor below to the maximum to minimise heat loss. If you can't insulate then don't bother. The install will cost you a fortune to run and not work very well.
I would also ensure it covers the entire exposed floor area as the heat doesn't radiate between tiles well at all. Make sure you have sufficient controls fitted as well.
There is a member on here who runs an ufh company / supplier but I can't remember who it is.
Google will throw up a good number of websites to look through.
mk1fan said:
I would also ensure it covers the entire exposed floor area as the heat doesn't radiate between tiles well at all.
This! You can tell exactly where the heating mat ends in our kitchen, one tile certainly doesn't heat the next!It is the sole heating source in our kitchen and we also have a plinth heater that we could switch on if it got especially cold, but we rarely use it!
22 degrees takes the edge off and around 26-28 radiates and heats the kitchen.
I was under the impression that heating a large surface area (like a kitchen) would be incredibly expensive to run (they're quite power hungry) and I'm not sure if I'd rely on it as a primary heat source.
We had it installed in our bathroom (3 metre square mat covered it) and it's lovely to take the chill off of the tiles in the morning and evening (set to 20 deg for those periods and 13 deg the rest of the day). We have then got a large towel radiator for more heat.
As it was upstairs on floor boards, we:
Hope this helps
We had it installed in our bathroom (3 metre square mat covered it) and it's lovely to take the chill off of the tiles in the morning and evening (set to 20 deg for those periods and 13 deg the rest of the day). We have then got a large towel radiator for more heat.
As it was upstairs on floor boards, we:
- screwed plywood down to level and secure
- poured screed
- set insulation mats and sealed joins once dry
- thin screed of flexible adhesive
- laid tiles in the conventional way
Hope this helps
Don't get electric for such a big area. I've got warmup in my en-suite and it is only really any good for making the floor nice and warm to walk on - it doesn't heat the room up (I still have a radiator to do that)
If it's to heat the kitchen and is to be installed on an existing floor, take a look at plumbed in solution. I recommend Polypipe Overlay:
http://www.freeyourwalls.com/products/overlay/
It consists of MDF panels with a groove cut into them for the pipework that you glue to the existing floor and it only adds 18mm to the floor height.
I had this fitted in my kitchen after someone on here recommended it and it's brilliant. It warms up much quicker than if the pipe was embedded in the screed and is perfect for single room applications IMO. Not expensive either.
I've got a separate thermostat in the kitchen so that it is controlled independently from the rest of the house heating
If it's to heat the kitchen and is to be installed on an existing floor, take a look at plumbed in solution. I recommend Polypipe Overlay:
http://www.freeyourwalls.com/products/overlay/
It consists of MDF panels with a groove cut into them for the pipework that you glue to the existing floor and it only adds 18mm to the floor height.
I had this fitted in my kitchen after someone on here recommended it and it's brilliant. It warms up much quicker than if the pipe was embedded in the screed and is perfect for single room applications IMO. Not expensive either.
I've got a separate thermostat in the kitchen so that it is controlled independently from the rest of the house heating
Furtive, the heat output of that stuff is nowhere near sufficient. I don't know anything about it but in comparison to the electric stuff I've been looking at it has half the heat output and is about 4 or 5 times as thick!
I can't really see any advantage to it. Am I missing something?
I can't really see any advantage to it. Am I missing something?
What makes you think the heat output would not be sufficient? It heats my kitchen up very well (where as the warmup electric stuff I've got in my en-suite doesn't warm that up anywhere near as well)
For reference, 100 W/m2 is the maximum output you can get from a screeded wet underfloor heating system
For reference, 100 W/m2 is the maximum output you can get from a screeded wet underfloor heating system
Edited by furtive on Monday 14th November 15:50
I don't know how far along you are on your build but if you want it done properly then get someone like Rehau to design a wet underfloor heating system for you. Pricey, but much cheaper to run in the long run.
With regard to your 200w panels, is that per m² or total? If it is total then imagine how hot your room would get with 2 x 100w light bulbs going. Not very! Look for an online radiator calculator to determine approximate heating requirements.
With regard to your 200w panels, is that per m² or total? If it is total then imagine how hot your room would get with 2 x 100w light bulbs going. Not very! Look for an online radiator calculator to determine approximate heating requirements.
furtive said:
What makes you think the heat output would not be sufficient? It heats my kitchen up very well (where as the warmup electric stuff I've got in my en-suite doesn't warm that up anywhere near as well)
For reference, 100 W/m2 is the maximum output you can get from a screeded wet underfloor heating system
Im not sure, really. What is the heat output of the electric stuff you have?For reference, 100 W/m2 is the maximum output you can get from a screeded wet underfloor heating system
The reading up I have done on electric ones generally makes the following guidelines:
100 w/m2 : effective only for warming the tiles
150 w/m2 : effective for warming tiles and heating well insulated rooms with average amount of windows
200 w/m2 : For areas that have higher heat loss from French doors/bad insulation etc
Now I don't know much but I would imagine that if the flooring puts out 100 w/m2 then it doesnt matter whether it is water-based or electric? The output is the identical?
SO for example-the w/m2 might be the same for your electric and plumbed heating but you have a double glazed kitchen whilst your bathroom has an old crap window?
Im just guessing
rsv gone! said:
I don't know how far along you are on your build but if you want it done properly then get someone like Rehau to design a wet underfloor heating system for you. Pricey, but much cheaper to run in the long run.
With regard to your 200w panels, is that per m² or total? If it is total then imagine how hot your room would get with 2 x 100w light bulbs going. Not very! Look for an online radiator calculator to determine approximate heating requirements.
Too late for plumbed in one unfortunately.With regard to your 200w panels, is that per m² or total? If it is total then imagine how hot your room would get with 2 x 100w light bulbs going. Not very! Look for an online radiator calculator to determine approximate heating requirements.
The electric stuff is w/m2 not total watts
We have this system in a 6 x 5 m home cinema and it is the only source of heating, to maintain a nice temp it has to be set at about30 to keep the room warm but is very heavy on the electric, as we now have the energy meter I can tell you it is costing about £6.00 a day to run just to heat that one room, and in the new extension we are laying wet underfloor heating for the simple reason that £42.00 per week to run is just to expensive and a wet system although more expensive to install will be a lot cheaper to run!
dazzalse said:
We have this system in a 6 x 5 m home cinema and it is the only source of heating, to maintain a nice temp it has to be set at about30 to keep the room warm but is very heavy on the electric, as we now have the energy meter I can tell you it is costing about £6.00 a day to run just to heat that one room, and in the new extension we are laying wet underfloor heating for the simple reason that £42.00 per week to run is just to expensive and a wet system although more expensive to install will be a lot cheaper to run!
True, but if you can afford a 30 m2 room purely to watch television and keep it heated 7 days per week, then I would have thought £2000 per year is a drop in teh ocean. And thats assuming its winter all year, which it isn't.A 15 m2 kitchen Ive worked out is going to cost about £2 per day to heat assuming it is on full for 10 hours per day (i.e. 4 months of the year).
I can live with that I think
Gatecrash time!
I've not yet done much research, but, is it relatively simple to put wet ufh underneath a solid wood floor?
At the moment I have just joists, on top of that I was going to put ply, then the solid wood. However, I'd quite like to put in ufh running off the condensing boiler (in the room next door)
Any thoughts or advice welcome thanks.
I've not yet done much research, but, is it relatively simple to put wet ufh underneath a solid wood floor?
At the moment I have just joists, on top of that I was going to put ply, then the solid wood. However, I'd quite like to put in ufh running off the condensing boiler (in the room next door)
Any thoughts or advice welcome thanks.
dirty boy said:
I've not yet done much research, but, is it relatively simple to put wet ufh underneath a solid wood floor?
At the moment I have just joists, on top of that I was going to put ply, then the solid wood. However, I'd quite like to put in ufh running off the condensing boiler (in the room next door)
Any thoughts or advice welcome thanks.
Polypipe have a suspended floor system that would be suitable:At the moment I have just joists, on top of that I was going to put ply, then the solid wood. However, I'd quite like to put in ufh running off the condensing boiler (in the room next door)
Any thoughts or advice welcome thanks.
http://www.freeyourwalls.com/products/suspended-fl...