Can anyone work this out?
Discussion
I'm in the middle of creating our potager / vegir garden & need to work out the pressure created by our rainwater tank to see if its sufficient at current height or if I'll need to lift it some more, probably best worked out at 1/2 tank (1 ton)
but I'm stumped on liquid weight v height v 19mm hose etc
anyone care to show off
scenario is this with 19mm hose:

but I'm stumped on liquid weight v height v 19mm hose etc
anyone care to show off

scenario is this with 19mm hose:
We need to know how far the surface of the stored water is above the outlet, to give you a proper calculation, but the answer is probably around 3-4 psi
http://www.accontrols.com/documents/FeetHeadofWate...
http://www.accontrols.com/documents/FeetHeadofWate...
Edited by sparkythecat on Tuesday 22 November 08:53
DavidY said:
Are you going to hose, sprinkle or seep output?
seepsparkythecat said:
We need to know how far the surface of the stored water is above the outlet, to give you a proper calculation, but the answer is probably around 3-4 psi
http://www.accontrols.com/documents/FeetHeadofWate...
[/footnote]
tank is only 12" off the ground, I guess I could lift it another 12" if it makes much of a difference, I guess it may well do to the 1/2 tank??http://www.accontrols.com/documents/FeetHeadofWate...
[/footnote]
OK, my first go....
http://www.efunda.com/formulae/fluids/draining_tan...
Gives an exit from the tank flow rate of 1.23 l/s
Then for the frictional loss in the pipe:
http://www.engineeringtoolbox.com/hazen-williams-w...
Head loss (mm H20) 20217.55
Head loss (kPa) 198.33
Calculated Flow Velocity
v = flow velocity (m/s) 4.34
Does that help? I'm curious and this was idle googling - IANAP (I am not a physicist)
http://www.efunda.com/formulae/fluids/draining_tan...
Gives an exit from the tank flow rate of 1.23 l/s
Then for the frictional loss in the pipe:
http://www.engineeringtoolbox.com/hazen-williams-w...
Head loss (mm H20) 20217.55
Head loss (kPa) 198.33
Calculated Flow Velocity
v = flow velocity (m/s) 4.34
Does that help? I'm curious and this was idle googling - IANAP (I am not a physicist)
I work in bar so bare with me! 0.1 bar per meter. So 2 meters from tank outlet to hose outlet if = 0.2 bar
0.2 bar is 2.9 PSI. That is the pressure. Lift the tank and you'll get more pressure. Increase the bore of the hose and it'll increase the flow not the pressure.
So if the outlet is at the bottom of the tank you'll get 2.9 PSI pressure. When the tank is full (1 meter high tank!?), you'll get 4.3 PSI pressure.
0.2 bar is 2.9 PSI. That is the pressure. Lift the tank and you'll get more pressure. Increase the bore of the hose and it'll increase the flow not the pressure.
So if the outlet is at the bottom of the tank you'll get 2.9 PSI pressure. When the tank is full (1 meter high tank!?), you'll get 4.3 PSI pressure.
zaphod42 said:
OK, my first go....
http://www.efunda.com/formulae/fluids/draining_tan...
Gives an exit from the tank flow rate of 1.23 l/s
Then for the frictional loss in the pipe:
http://www.engineeringtoolbox.com/hazen-williams-w...
Head loss (mm H20) 20217.55
Head loss (kPa) 198.33
Calculated Flow Velocity
v = flow velocity (m/s) 4.34
Does that help? I'm curious and this was idle googling - IANAP (I am not a physicist)
interesting stuff, particularly the friction loss in the hose pipe http://www.efunda.com/formulae/fluids/draining_tan...
Gives an exit from the tank flow rate of 1.23 l/s
Then for the frictional loss in the pipe:
http://www.engineeringtoolbox.com/hazen-williams-w...
Head loss (mm H20) 20217.55
Head loss (kPa) 198.33
Calculated Flow Velocity
v = flow velocity (m/s) 4.34
Does that help? I'm curious and this was idle googling - IANAP (I am not a physicist)
love that detail Not sure I have the right end of the stick, but flow velocity would indicate speed rather than quantity wouldn't it? so not sure if its a help or not

netherfield said:
No idea about the flow,but fit a lid on the tank to exclude light or eventually it will go green and fur up the insides of your pipes and bung up your seep hose.
good point, though it's an outside tank which collects rain water directly into the top of the tank, its not fed by any guttering etc so I'd need to fit a foam filter to the top of some kind I think, would stop some UV and filter other undesired particles, no biggy as i have to fit a wire mesh cover to the top to stop the leaves, i could attach foam to underside, maybe there's a pond filter foam that acts as an anti bacteria as well??jefword said:
For every 12 inches that the surface of the water in your tank is above the outlet, you will get 0.433 PSI irrespective of the pipe diameter.
Hence to get 4 PSI at the outlet, the surface would have to be about 9ft 3" above the end of your pipe.
Hope this helps.
(It won't if I'm wrong)
Hence to get 4 PSI at the outlet, the surface would have to be about 9ft 3" above the end of your pipe.
Hope this helps.
(It won't if I'm wrong)
so have I got the right end of the stick when I say it'll drop by 1.2 psi when the tank gets near empty? (near as damn it) if right, then lifting by 12" might be worth it to alleviate the psi loss as it empties.Gingerbread Man said:
Increase the bore of the hose and it'll increase the flow not the pressure.
I'd like the tank to last 1 week in summer if possible but I think we might be pushing things.
eta: requirements are going to be 190l a day so should still have 600l left at end of week, minus some evaporation (though its 2" thick concrete container) should see 400l left, this should negate the need to lift another 12"
but rising 12" when the outlet meets the raised beds may still mean the need to lift
now I have some formulas to work with I'll get out there with a level today & work out more accurately.thanks chaps
Edited by Pvapour on Wednesday 23 November 07:54
Yes you have the right end of the stick as you put it. Pressure has nothing to do with the tank outlet, only the height of the surface of the water in comparison to the height of the outlet end of your hose.
If you loop your hose up in a U shape so that the end is at the same height as the tanks water level, the pressure will be zero.
Your calculation of a 1 metre drop in water level being about 1.2 psi is also correct.
If you loop your hose up in a U shape so that the end is at the same height as the tanks water level, the pressure will be zero.
Your calculation of a 1 metre drop in water level being about 1.2 psi is also correct.
Gassing Station | Homes, Gardens and DIY | Top of Page | What's New | My Stuff



