Fire doors - opinions wanted.
Fire doors - opinions wanted.
Author
Discussion

andy-w

Original Poster:

1,987 posts

257 months

Thursday 1st December 2011
quotequote all
Hi guys,

Hopefully one of you lot will be able to help me.
I have been told that i need to fit some fire doors in a building....not a problem, hanging doors is easy but the intumescent strips, will i be able to use a router on the edge of the door and mount the strips there or would they have to be mounted on the door frames...i can get cheap fd30 fire doors from b&q and intumescent strips from screwfix, i just think it will be easier using a router on the doors rather than the frames....

open to any suggestions.

Cheers

Wings

5,985 posts

246 months

Thursday 1st December 2011
quotequote all
Mine are all on doors, but can be applied to frame. If for a BTL and fitting door lock furniture, requirements are that the inside lock should have a turn button, so no key required to unlock door. Just thought i would mention that.

Chuggy

364 posts

194 months

Thursday 1st December 2011
quotequote all
Be very, very careful. An FD30 door does not make an FD30 Door-set.

Yes, you will need intumescents. You also need to be mindful of the hanging tolerances, hinges, seals behind the hinges and keeps. If that's not enough, also needs to be considered is the width of the frame on the fire-side of the opening as well as it's density and how it is fixed to the substrate.

Or you could router grooves on three sides of the door, fit intumescents, hope you have a building inspector who is not up-to-date with the regulations and sleep well at night knowing you have put lives at risk.


andy-w

Original Poster:

1,987 posts

257 months

Thursday 1st December 2011
quotequote all
Chuggy said:
Be very, very careful. An FD30 door does not make an FD30 Door-set.

Or you could router grooves on three sides of the door, fit intumescents, hope you have a building inspector who is not up-to-date with the regulations and sleep well at night knowing you have put lives at risk.

Bit extreme...!

I should also add that the building was used as an othoppaedic clinic, was inspected and told they omly needed one fire door, now a few years later we have bought the building and the fire officer said every door has to be a fire door...daft thing is we are directly across the road from the firestation....!!!!!!!!!!!


I just think he is being a bit ott...its basically the size of a 3 bed detached house....10m x 12 footprint...!

rvttim

73 posts

189 months

Thursday 1st December 2011
quotequote all
Im assuming the building is to work in. If it is then thats why the fire inspectors been round.

If you alter a fire door in any way then it looses its waranty. To gain the proper requirments as said before you will need to fit a door set, new frame and door, with the required intumisent slots pre cut by the manufacturer including hinge cut outs.

Wings

5,985 posts

246 months

Thursday 1st December 2011
quotequote all
rvttim said:
Im assuming the building is to work in. If it is then thats why the fire inspectors been round.

If you alter a fire door in any way then it looses its waranty. To gain the proper requirments as said before you will need to fit a door set, new frame and door, with the required intumisent slots pre cut by the manufacturer including hinge cut outs.
Will the fire door also need to be self closing?

rvttim

73 posts

189 months

Friday 2nd December 2011
quotequote all
Will the fire door also need to be self closing?

Yes