Boiler and gas pressure.
Discussion
Hi all,
I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
Road2Ruin said:
Hi all,
I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
I think that means the pipe between the meter and boiler isn't big enough, doesn't it?I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
Arthur Jackson said:
Road2Ruin said:
Hi all,
I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
I think that means the pipe between the meter and boiler isn't big enough, doesn't it?I have had a problem with the boiler recently and the engineer when he came to look at it commented on the pressure drop when the boiler was running at full blast. The pressure at the meter is 27mb and pretty much the same at the boiler. However, whent he boiler is running at full he said it dropped to about 16mb and it should only drop a maximum of 1 mb ehn on full! Is this right? I thought the 1 mb drop thing reffered to a static pressure drop when the boiler is not running. The long and the short of it is that they are refusing to work on it until I sort this out. So would be nice to have the right info to knwo what to do. It is a Remeha so hopefully Ferg will have some good advice.
Ta V Much.
How long is the run OP? and what is it feeding?
Over 1mb drop from meter to boiler and pipework probably at fault. Too small, too many restrictions, blocked in some way or other, damaged, etc...
We have a 28mm pipe from meter for about 15m then 5m of 22mm, then 1m of 15mm to boiler! I could change the last 1m to 22. But I would like to know what this 1mb drop refers to? From reading on internet it's as clear as mud! It appears to say that the pressure drop between meter and bolier should be no more than 1mb. It isnt. The pressure drop occours when you turn the boilef on full. The pressure the drops from 27mb to 16mb, both read at boiler! Nothing was read at meter when boiler was running. Any help?
May help with working out your pipe sizing.
http://www.ukcopperboard.co.uk/literature/pdfs/Ins...
Testing
http://www.ukcopperboard.co.uk/literature/pdfs/Ins...
http://www.ukcopperboard.co.uk/literature/pdfs/Ins...
Testing
http://www.ukcopperboard.co.uk/literature/pdfs/Ins...
Its a 39kw, a 1m run should be fine. I know how pipe sizing works. Its this 1mb pressure drop that is confusing me as I think he may be reading it wrong but dont know for sure. If the boiler is on should the pressure be read at the meter, then at the boiler to calculate the drop? If so this is not how he did it. He took the reading when the boiler was off at the meter and then at the boiler when it was on full blast! Not sure if that is right. It's not a problem to change the 1m of 15mm to 22mm if needed as it is all exposed.
I think the 1mb drop is the difference in working pressure at full rate at the meter test point and the inlet of the appliance.
Sounds like he is measuring the difference between standing and working pressure at the appliance inlet!
I'd be tempted to change that last bit of 15mm to 22mm, seems a bit small for a 37KW boiler.
Sounds like he is measuring the difference between standing and working pressure at the appliance inlet!
I'd be tempted to change that last bit of 15mm to 22mm, seems a bit small for a 37KW boiler.
With the boiler running at its highest rate the difference between the pressure at the meter and the pressure at the boiler should be no greater than 1mb. The pressure at the meter should be 20mb when the boiler is running, if it is less than 20mb there may be a problem with the govener on the meter.
Is this a combi, what model?
What is the original fault?
Caveat, It's years since I did this.
A boiler normally has two test points one before the gas enters the burner & one on the burner/gas-valve for testing burner pressure.You can have much more than a 1mb drop on full chat but that can be down to a fault on the burner or the governor.
Some boilers can't have the burner pressure measured accurately with a manometer as they are modulating, they go up/down depending on call for heat.
You can do a two minute gas rate check from the meter (dial or metric digit readings)(count the revolutions or digits)and see how much gas k/w is being burnt then confirm that its within the manufacturers limits on the data plate on the boiler.
The governor as has been already mentioned may be at fault & not providing enough on demand or the burner itself is out of tolerance.
What is the original fault?
Caveat, It's years since I did this.
A boiler normally has two test points one before the gas enters the burner & one on the burner/gas-valve for testing burner pressure.You can have much more than a 1mb drop on full chat but that can be down to a fault on the burner or the governor.
Some boilers can't have the burner pressure measured accurately with a manometer as they are modulating, they go up/down depending on call for heat.
You can do a two minute gas rate check from the meter (dial or metric digit readings)(count the revolutions or digits)and see how much gas k/w is being burnt then confirm that its within the manufacturers limits on the data plate on the boiler.
The governor as has been already mentioned may be at fault & not providing enough on demand or the burner itself is out of tolerance.
Edited by 69 coupe on Friday 2nd December 19:54
I'd assume your 27mbar is standing pressure and means nothing. You should have 21mbar plus or minus 2mbar working pressure at the gas meter when the boiler is at full rate, you are then looking for a maximum 1mbar drop from this at the boilers inlet working pressure test point (21 at meter 20 at the boiler) First thing you need to know is what the working pressure at the meter is as it wont be 27mbar!
Edited by BIGMIKE1 on Friday 2nd December 22:51
Thanks chaps. I'm not sure there is an issue with the pressure, just the way they measured it sounds wrong. The boiler trips occassionally with an e5 fault 'no co2 ionisation'. This could be a number of things but the engineer wont work on it while he says the pressure is wrong! I dont think it is...
Road2Ruin said:
Thanks chaps. I'm not sure there is an issue with the pressure, just the way they measured it sounds wrong. The boiler trips occassionally with an e5 fault 'no co2 ionisation'. This could be a number of things but the engineer wont work on it while he says the pressure is wrong! I dont think it is...
If there is more than 1mb pressure drop at the gas inlet with the boiler running at high he is right, Remeha specify a gas inlet pressure of no less than 17mb.I've worked on loads of boilers where the inlet pressure is less than 17, if it's causing a problem with the ignition or not giving enough heat then yes, it needs addressing. As someone mentioned previously, gas rate it and see exactly how much gas it's burning. If thats ok then I wouldn't worry about it.
Gassing Station | Homes, Gardens and DIY | Top of Page | What's New | My Stuff


