Aqualisa HiQu Digital
Discussion
I installed a Aqualisa HiQu digital power shower earlier this year, the one that goes in the loft and is above the shower head in our (semi) wet room, it has started to make a noise now when turned on initially, plus it stops for a couple of seconds after about five seconds of running and then restarts.
I have spoken to the customer helpline and they have said it sounds like air in the system and have given me a procedure to eliminate it, but the problem still exsits. Before they send an engineer out should I put a non return valve in the hot and cold feed (although the cold feed from the tank is only about 6ft away). I guess the hot is more prone to air as the feed is from the hot tank which is about 25ft away?
I only ask this as I will be charged if it's not a pump fault, no problem with this, but if I can fix it then all the better.
Cheers
Graham
I have spoken to the customer helpline and they have said it sounds like air in the system and have given me a procedure to eliminate it, but the problem still exsits. Before they send an engineer out should I put a non return valve in the hot and cold feed (although the cold feed from the tank is only about 6ft away). I guess the hot is more prone to air as the feed is from the hot tank which is about 25ft away?
I only ask this as I will be charged if it's not a pump fault, no problem with this, but if I can fix it then all the better.
Cheers
Graham
I have a similar model, and that also does a bit of umming and arring before a constant flow is achieved. 25 feet sounds like a very long run so my hunch is that the pump is building up pressure and having a bit of a struggle. Do the instructions mention a maximum recommended feed length?
I'd look closely at how the hot is connected. Any air is obviously going to rise to the unit, or possibly to the point where the pipework turns from vertical to horizontal especially if the pipework falls slightly to the processor unit. How does it connect to the hot supply? Secondary tapping? Essex flange? Surrey Flange? Tee on the draw off? Tee on the vent..(hopefully not!)?
Not sure if it's an Essex or Surrey but here's acouple of pictures of the hot tank. The pipework to the Aqualisa is the 22mm pipe going up into the loft, the 15mm pipe tee'd goes down to the pump for the bathroom (we don't run them at the same time).


Do I need to put a bleed valve in the 22mm pipe in the loft where it bends 90o elbow towards the pump?
Graham
Do I need to put a bleed valve in the 22mm pipe in the loft where it bends 90o elbow towards the pump?
Graham
Graham-P said:
Not sure if it's an Essex or Surrey but here's acouple of pictures of the hot tank. The pipework to the Aqualisa is the 22mm pipe going up into the loft, the 15mm pipe tee'd goes down to the pump for the bathroom (we don't run them at the same time).


Do I need to put a bleed valve in the 22mm pipe in the loft where it bends 90o elbow towards the pump?
Graham
Looks OK, to be honest. You could put a bleed there, but I'd expect the pump to clear it once it's run for a bit. It sounds like it's gathering some air when it's stationary? I take it it does run fine after the 5 second stop-then-start phase? Difficult to see where the air is coming from, although the Surrey Flange does have a diverting 'mushroom' to stop air from the heating effect of the coil going straight up into the pipework...I suppose that might have come adrift??Do I need to put a bleed valve in the 22mm pipe in the loft where it bends 90o elbow towards the pump?
Graham
Yellow bit here...