further to mu question about running cabling i was wondering if i could stick a 13 amp socket in line with a light switch in the loft ?

Megaflow

11,698 posts

256 months

Wednesday 14th December 2011
quotequote all
yikes

No..........

Podie

46,650 posts

306 months

Wednesday 14th December 2011
quotequote all
Megaflow said:
yikes

No..........
This!

yikes

CoolC

4,513 posts

245 months

Wednesday 14th December 2011
quotequote all
Does the light in the loft run off the lighting ring or the ring main?

Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
no idea yet smile

why cant it be done ?

what other way would there be to get a socket up there ?

obviously i dont want to do anything stupid and obviously it needs to be legit as the house is not even 6 months old yet

freecar

4,249 posts

218 months

Wednesday 14th December 2011
quotequote all
I run a 13 amp socket from the lighting ring in the loft.

I ONLY use it for a 60w bulb though!

So now instead of one bulb at the top of the stairs it sometimes runs two.

If you wanted to plug something into it forget it, the circuit isn't designed to carry any real load.

Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
im talking an 8 port switch
power requirements like this
Power adapter: 12W, 12V DC, 1A
Maximum power consumption:
- 4.92W (if cable length > 10 m)
- 4.08W (if cable length < 10 m)

Megaflow

11,698 posts

256 months

Wednesday 14th December 2011
quotequote all
Trustmeimadoctor said:
no idea yet smile

why cant it be done ?

what other way would there be to get a socket up there ?

obviously i dont want to do anything stupid and obviously it needs to be legit as the house is not even 6 months old yet
Assuming it will be connected to a lighting circuit, not a ring main, then a lighting circuit is designed to handle 6 amps, not 32 amps your ring main is designed to handle.

Putting a 13a socket on a lighting circuit is a very good way of testing how your house insurance provider will deal with the results of a fire!

Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
in that case what way can i do it ? im rather attached to the house smile

mk1fan

10,920 posts

256 months

Wednesday 14th December 2011
quotequote all
why not fit a 5amp fused spur connection unit instead of a socket and hardwire the port?

The issue you need to ressolve is someone assuming it's on the ring main and plugging in something that draws more than the circuit can take. You saying 'I won't do that' is not sufficient.

cjs

11,733 posts

282 months

Wednesday 14th December 2011
quotequote all
What you should do is run a 2.5mm T&E cable from the distribution board. But that's easier said than done.

If there is no 32a ring main in the loft and you really have to use the lighting circuit then do not install a 13a socket but fit a fused, switched spur instead, you can then use a 3a fuse.

Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
tbh i was surprised when i found they hadnt put a socket up there seems a bit cheep to me

mk1fan

10,920 posts

256 months

Wednesday 14th December 2011
quotequote all
Too slow!

cjs

11,733 posts

282 months

Wednesday 14th December 2011
quotequote all
Trustmeimadoctor said:
tbh i was surprised when i found they hadnt put a socket up there seems a bit cheep to me
Yes.

Is there no boiler, HW tank with immersion in loft? What about TV aerial distribution?


Edited by cjs on Wednesday 14th December 12:29

cjs

11,733 posts

282 months

Wednesday 14th December 2011
quotequote all
Can you fish down a stud wall to a 13a socket in one of the bedrooms?

cjs

11,733 posts

282 months

Wednesday 14th December 2011
quotequote all
mk1fan said:
Too slow!
At least we agree!


Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
so easy way to see if its a mains circuit turn light on in loft then turn the upstairs sockets circuit off if its still on its on lighting if its off its on a suitable ring ?

the outside light at the front is on the socket ring as i found out to my surprise when i was rewiring the switch!!! turned lighting ciruit off thought naivly that will do but oh no bang angel

Trustmeimadoctor

Original Poster:

14,377 posts

186 months

Wednesday 14th December 2011
quotequote all
cjs said:
Yes.

Is there no boiler, HW tank with immersion in loft? What about TV aerial distribution?


Edited by cjs on Wednesday 14th December 12:29
actually why didnt i think of that totally forgot that there was the distribution unit up there !! strange as i was playing with it last night aswell.

will just swap that out for a double socket then !

dickymint

29,278 posts

289 months

Wednesday 14th December 2011
quotequote all
Trustmeimadoctor said:
cjs said:
Yes.

Is there no boiler, HW tank with immersion in loft? What about TV aerial distribution?


Edited by cjs on Wednesday 14th December 12:29
actually why didnt i think of that totally forgot that there was the distribution unit up there !! strange as i was playing with it last night aswell.

will just swap that out for a double socket then !
Why bother? Just plug in a 2 way adapter.

cjs

11,733 posts

282 months

Wednesday 14th December 2011
quotequote all
Trustmeimadoctor said:
actually why didnt i think of that totally forgot that there was the distribution unit up there !! strange as i was playing with it last night aswell.

will just swap that out for a double socket then !
Sorted!

Although I would check they have put that socket on the correct circuit and not on the lighting circuit.