Building/Fire Regs - Advice Req
Building/Fire Regs - Advice Req
Author
Discussion

MATTP77

Original Poster:

697 posts

226 months

Thursday 15th December 2011
quotequote all
PHers!

Looking at buying my first place, and the idea is to rent it out (or at least initially, as I am working away from home at the moment).

Before we start, i must stress, sadly, that a family friend's friends are selling this due to their daughter passing away very unexpectedly so they are after getting rid of it asap.

Because of the above, ive been given first refusal at a competitive price. They are just waiting for the legal bits and bobs to be finalised before it is signed over to them.

When i was being shown around, just before we walked up to the converted loft room, I was told upfront that the works hadnt been done to building regs. Now as far as i am concerned this is basically in reference to the stairway which leads from the 1st floor landing to the converted attic room.

Pics (sorry for crap quality and even worse aspect!)



and;


Now as this conversion was done between 5-10 years ago, does this mean that as far as building control are concerned, that it needs no authorisation now?

Now the stairs are the problem. I want to rent this property out as a 3 bedroom, which obviously ups the rental value considerably, but ive been told by a colleague that because stairs are not to building regs, in that the rise ans tread are none compliant (is there anything else to comply with?) that i couldnt advertise this as a bedroom, for access/egress reasons.

OK so i feel i have said too much, and i've blurred my problem as much as possible, so ill stop.

Just how do i go about renting it as a 3-bed and if i need to change things, what am i likely needing to change?

Thanks guys!!

silverthorn2151

6,413 posts

210 months

Thursday 15th December 2011
quotequote all
The fundamental issue with loft conversions is that they change the nature of the dwelling to three stories. As such it triggers a set of requirements that relate to fire precautions.

From what I can make out in the picture the stairs open directly into the loft room. That's a problem in and of itself. Is there a window, either velux or dormer, than can be used for escape (there are specific dimensions and distances in the building regs relating to this, but for the moment it's just of there is, or isn't a suitable window).

My instinct is that you'll have a nightmare upgrading the conversion to comply with the building regs. You don't actually have to, as thee will be enfocrement action taken, but renting it out is slightly different. You may find that in the event of future sale someone goes throughthe same considerations as you.

Probably best to stick with 2 bedroom as a description.

It is, of course, difficult to be precise on the basis of little information. A local Building Surveyor could give you more specific advice for a few hundred quid. You may consider that money well spent in the long term.

Busa mav

2,850 posts

185 months

Thursday 15th December 2011
quotequote all
The ground floor layout is also important to see in this instamce.