Changing a light switch without killing the electric
Discussion
I have a bit of a problem downstairs whereby the motion sensor switch I have fitted in our garage has broken and the light is permanently switched on. Apart from costing me a small fortune, it means anyone passing by can easily see the items we have in our garage.
Unfortunately the electric is wired through the community garage fuse box switch and cannot be turned off by myself. (Weird wiring here in Spain). I've requested the maintenance guy switch it off but it's all falling on deaf ears and after three weeks, I want to fix the problem ASAP.
So, my question is can I replace the light switch without killing the electric supply by using some industrial rubber gloves to insulate my hands from the current?
Has anyone done this before? Is it safe?
Unfortunately the electric is wired through the community garage fuse box switch and cannot be turned off by myself. (Weird wiring here in Spain). I've requested the maintenance guy switch it off but it's all falling on deaf ears and after three weeks, I want to fix the problem ASAP.
So, my question is can I replace the light switch without killing the electric supply by using some industrial rubber gloves to insulate my hands from the current?
Has anyone done this before? Is it safe?
ok ok! Sounds a bit mad, but these are the gloves I'm talking about:
http://www.marigoldindustrial.com/us/industrial-gl...
I don't know what options I have if I can't get the electric switched off....
http://www.marigoldindustrial.com/us/industrial-gl...
I don't know what options I have if I can't get the electric switched off....

Seriously though, I work in a large electricity distribution company and I just asked one of the field engineers if it could be done. He said yes, but not by someone who didn't know what they were doing, he said there's a very high chance of getting a hit even if you know what you're doing!
I have done this before in the UK - in fact I always used to do that until the latest ELCBs meant that even if I didn't switch it off, the break in circuit as I removed the live or neutral would trip it for me. It must be said I know knack all about Spain but I would guess based on things I have seen out there when visiting it could be less safe.
Essentially, in the UK in a single switch there is permanent a live feed, neutral (sometimes multiple wires meaning it is difficult to handle them when live) and a switched live out to the bulb - maybe more if the switch is two way for example. Beware of both anything in the live and neutral - handle with insulated pliers if you are that bothered and watch for the flash when disconnecting either. Personally, I don't mind the odd tickle from electrics, but if you are scared leave well alone. AC current had a nasty habit of making you grab hold of it when you get a belt and you are apprehensive.
Don't forget to take a picture, noting the labels on the posts as sometimes they get switched around in different manufacturers plates. Also, don't forget to video yourself doing it so we can have a good laugh at you getting a belt
What could possibly go wrong?
Essentially, in the UK in a single switch there is permanent a live feed, neutral (sometimes multiple wires meaning it is difficult to handle them when live) and a switched live out to the bulb - maybe more if the switch is two way for example. Beware of both anything in the live and neutral - handle with insulated pliers if you are that bothered and watch for the flash when disconnecting either. Personally, I don't mind the odd tickle from electrics, but if you are scared leave well alone. AC current had a nasty habit of making you grab hold of it when you get a belt and you are apprehensive.
Don't forget to take a picture, noting the labels on the posts as sometimes they get switched around in different manufacturers plates. Also, don't forget to video yourself doing it so we can have a good laugh at you getting a belt

What could possibly go wrong?

That would be the obvious choice, yes but it's the same problem. There are four fluorescent tubes lighting up our garage space and to remove them involves rotating each end to unlock them which is just as precarious as the light switch as it's so close to the contact...
I've already had a go, but without the aforementioned insulating gloves, I'd rather not try it with my bare hands.
I've already had a go, but without the aforementioned insulating gloves, I'd rather not try it with my bare hands.
Edited by beanbag on Monday 29th December 13:46
Yes you can replace the switch while it's still live, you don't need rubber gloves, you just need a screwdriver with an insulated handle and make sure you don't touch any of the wires. This is what I would do but if you don't know what you're doing it might be safer if you don't do it! Taking the bulb out is safer. Your responsibility if you get a shock!!
If there are trips they should trip out as soon as you touch a live wire, but I wouldn't try it just in case.
When you disconnect and reconnect the wires you might trip the power off anyway - in fact you could deliberately trip it by shorting the wires across the switch, you could then replace it and when the maint man puts the trip back in it will all work properly again. This is assuming that with your funny Spanish wiring there are trips not fuses.
If there are trips they should trip out as soon as you touch a live wire, but I wouldn't try it just in case.
When you disconnect and reconnect the wires you might trip the power off anyway - in fact you could deliberately trip it by shorting the wires across the switch, you could then replace it and when the maint man puts the trip back in it will all work properly again. This is assuming that with your funny Spanish wiring there are trips not fuses.
I'm not suggesting for a minute that you work on a live circuit, but, if it's a recent-ish build, Spanish regs require that there should be an RCD in the Consumer Unit for the garages. If there is, and you touch something you shouldn't, the RCD will trip. Assuming it works of course. I'd never rely on one I hadn't tested first.
The easiest solution through, as someone else posted, is to remove the bulb, until your community electrician turns off the circuit.
The easiest solution through, as someone else posted, is to remove the bulb, until your community electrician turns off the circuit.