Old Drinks Cabinet Advice Please (electrical)
Old Drinks Cabinet Advice Please (electrical)
Author
Discussion

Steg O'Saurus

Original Poster:

126 posts

295 months

Saturday 17th January 2015
quotequote all
I am hoping someone from the diverse backgrounds on here can help me with this one. I've just bought a beautiful old drinks cabinet from 1960 which has a lamp inside, the plug is an old bayonet fitting and the wire looks threadbare so I want to replace it to work with a modern 3 pin mains plug. Has anyone done this and what's involved? Many thanks for any help.


Oakey

27,984 posts

247 months

Saturday 17th January 2015
quotequote all
What's involved?

I'm guessing splicing the live, neutral and earth and wiring them into a 3pin plug?

Steg O'Saurus

Original Poster:

126 posts

295 months

Sunday 18th January 2015
quotequote all
There are only two wires red and black (no earth) and the switch is currently connected as shown below...


Oakey

27,984 posts

247 months

Sunday 18th January 2015
quotequote all
Plug it into this and see what happens?

http://www.ebay.co.uk/itm/like/111279898823?limghl...

hidetheelephants

36,468 posts

224 months

Sunday 18th January 2015
quotequote all
Steg O'Saurus said:
There are only two wires red and black (no earth) and the switch is currently connected as shown below...

The switch and the lamp holders(looks like a 60w strip light fitting) look like plastic or ceramic, so unless the body of the cabinet is metal then just replacing the frankly scary old wire with new 2-core pvc flex and a 3 pin plug. Dead easy.

Steg O'Saurus

Original Poster:

126 posts

295 months

Sunday 18th January 2015
quotequote all
hidetheelephants said:
The switch and the lamp holders(looks like a 60w strip light fitting) look like plastic or ceramic, so unless the body of the cabinet is metal then just replacing the frankly scary old wire with new 2-core pvc flex and a 3 pin plug. Dead easy.
Thanks for the help, also the wires were twisted together somehow (on the bare bits below the switch in the photo) but the connection insulation pieces just crumbled away. The plunger on the switch is held in when you open the door. How should these wires be connected for that to work correctly with my new 2 core wire?

hidetheelephants

36,468 posts

224 months

Sunday 18th January 2015
quotequote all
Neutral wire goes to the lamp holder on the left, Live wire goes to the switch; cut a length of the flex and split it to get a length of wire to connect the switch to the right hand lamp holder.

Steg O'Saurus

Original Poster:

126 posts

295 months

Sunday 18th January 2015
quotequote all
hidetheelephants said:
Neutral wire goes to the lamp holder on the left, Live wire goes to the switch; cut a length of the flex and split it to get a length of wire to connect the switch to the right hand lamp holder.
Thanks a lot.

SPR2

3,220 posts

227 months

Sunday 18th January 2015
quotequote all

I too inherited an old drinks cabinet (don't know exactly how old) but is this wiring ok or need replacing? Would like to see your cabinet to compare era please.

hidetheelephants

36,468 posts

224 months

Sunday 18th January 2015
quotequote all
It looks like what's commonly called bell wire, because that's what it's often used for; if the insulation is still flexible and not cracked or sticky then it's probably alright, although replacing it with new cable with an outer sheath would make the wiring safer.

Edited by hidetheelephants on Sunday 18th January 16:17

0a

24,164 posts

225 months

Sunday 18th January 2015
quotequote all
Let's see a photo of the cabinet!

Pheo

3,560 posts

233 months

Sunday 18th January 2015
quotequote all
I'd replace it for safety's sake. Insulators could well be passed it. Depends if they are rubber or not though mainly. If they are, rip and replace. I'd use led strip in a profile or similar (12v, nice and safe wink)

hidetheelephants

36,468 posts

224 months

Sunday 18th January 2015
quotequote all
Pheo said:
I'd replace it for safety's sake. Insulators could well be passed it. Depends if they are rubber or not though mainly. If they are, rip and replace. I'd use led strip in a profile or similar (12v, nice and safe wink)
Which will have to have a 12v supply, which are a leading cause of electrical fires; you mentioned safety? wink

Steg O'Saurus

Original Poster:

126 posts

295 months

Sunday 18th January 2015
quotequote all
Here's mine, it's a 1960 Beautility...


Steg O'Saurus

Original Poster:

126 posts

295 months

Sunday 18th January 2015
quotequote all
...also mine needs a handle. If anyone can point me in the direction of one of these, I would be eternally grateful as I can't source one anywhere! It is 145mm between hole centres.


SPR2

3,220 posts

227 months

Monday 19th January 2015
quotequote all


A very different one. Anyone any idea how old this might be.?
It belonged to my late stepfathers family and he died in 1992 at the age of 83 years.


Edited by SPR2 on Monday 19th January 14:39

Pheo

3,560 posts

233 months

Monday 19th January 2015
quotequote all
hidetheelephants said:
Which will have to have a 12v supply, which are a leading cause of electrical fires; you mentioned safety? wink
Good point.

Buy a DECENT one! Not the cheapest tat you can get off Ebay!

Steg O'Saurus

Original Poster:

126 posts

295 months

Tuesday 20th January 2015
quotequote all
SPR2 said:
A very different one. Anyone any idea how old this might be.?
If you have a look on the back (possibly top right corner) mine had a date stamp of 1960.

hidetheelephants

36,468 posts

224 months

Tuesday 20th January 2015
quotequote all
Steg O'Saurus said:
SPR2 said:
A very different one. Anyone any idea how old this might be.?
If you have a look on the back (possibly top right corner) mine had a date stamp of 1960.
I have no idea, but the decor on SPR's is vaguely deco-looking which would suggest 1930s.

SPR2

3,220 posts

227 months

Tuesday 20th January 2015
quotequote all
Yes could have possibly been that early when I think about when he died and how long ago. I vaguely remember my mother telling me it had been made for his family but I cannot find a date on it.
I must admit it is very useful though.