Have just moved into a 4 year old house and it has continuously running extractor fans in the bathrooms and kitchens, they are produce a noise which is particularly noticeable in the kitchen.

Do these fans need to be left on ? And have extractor fans moved on in 4 years ?

B17NNS

18,506 posts

277 months

Monday 30th July 2018
quotequote all
Do you know what kind of system you have?


rs4al

Original Poster:

954 posts

195 months

Monday 30th July 2018
quotequote all
I think they are decentralised mechanical extraction ventilation (dMev) fans as they all have their own power supply. They are also branded Taylor wimpey, so am thinking they will be the cheapest fan available!

shady lee

962 posts

212 months

Monday 30th July 2018
quotequote all
Sounds like a possible humidity issue, we had huge humidity upstairs in our house so we fitted a nuaire drimaster piv unit, works a treat.

No condensation, humidity around 60% no higher.

B17NNS

18,506 posts

277 months

Monday 30th July 2018
quotequote all
So top left then. Have you tried adjusting the timer settings?

Equus

16,980 posts

131 months

Monday 30th July 2018
quotequote all
B17NNS said:
So top left then.
No, more like bottom left, but without the centralised unit.

dMEV works on the same principle as whole house MEV, but decentralised (ie. individual fans for each room, rather than ducting to a single centralised unit).

If it is dMEV, then the answers to the OP's questions are:
  • yes, or you'll almost certainly run into moisture control problems (if the system is dMEV, the extract rates won't be anything like powerful enough to control it if run intermittently), and;
  • no, not much.

Pheo

3,559 posts

232 months

Monday 30th July 2018
quotequote all
I’ve installed Vent Axia Svara fans which run continuously and then spool up when they detect a change in conditions (eg light coming on or humidity going up). Can adjust all the settings via Bluetooth eg speed, and can be configured to run in silent mode only during certain times of day.

Very happy with them overall and can hardly hear them - certainly not outside the room. Only challenge is they are a little bit spendy.

robemcdonald

10,037 posts

226 months

Monday 30th July 2018
quotequote all
I work for a ventilation manufacturer, whose name has already come up in a previous post.

it sounds like you have a decentralised MEV system. The fans need to run continuously for the system to work. You should also have trickle vents in the habitable rooms. You need to make sure these are open as well.

In terms of moving the technology on. The fans you have are most likely axial type. They are fine providing the duct runs aren’t too long. Moving to a centrifugal type fan would be quieter and cope more easily with higher pressure duct runs.

Let me know if you need further help.

Edited by robemcdonald on Monday 30th July 21:07

rs4al

Original Poster:

954 posts

195 months

Monday 30th July 2018
quotequote all
Thanks guys for the replies, will probably upgrade the fans once settled in.

Axial flow vs centrifugal, bit like superchargers and jet engines.

Edited by rs4al on Monday 30th July 21:29

shady lee

962 posts

212 months

Monday 30th July 2018
quotequote all
robemcdonald said:
I work for a ventilation manufacturer, whose name has already come up in a previous post.

it sounds like you have a decentralised MEV system. The fans need to run continuously for the system to work. You should also have trickle vents in the habitable rooms. You need to make sure these are open as well.

In terms of moving the technology on. The fans you have are most likely axial type. They are fine providing the duct runs aren’t too long. Moving to a centrifugal type fan would be quieter and cope more easily with higher pressure duct runs.

Let me know if you need further help.

Edited by robemcdonald on Monday 30th July 21:07
If your company resides in Wales....


Tell your company they do a brilliant piv system, even better when paired with the humidity sensor.

Also ask if the heater elements can be retro fitted to a non heat eco HC.

Ta

frisbee

5,621 posts

140 months

Monday 30th July 2018
quotequote all
rs4al said:
Thanks guys for the replies, will probably upgrade the fans once settled in.

Axial flow vs centrifugal, bit like superchargers and jet engines.

Edited by rs4al on Monday 30th July 21:29
I’ve got similar in my house. I leave them off, unless I’m showering or boiling something for a while in the kitchen. They are pretty rattly. No problems with condensation at all.

robemcdonald

10,037 posts

226 months

Tuesday 31st July 2018
quotequote all
shady lee said:
If your company resides in Wales....


Tell your company they do a brilliant piv system, even better when paired with the humidity sensor.

Also ask if the heater elements can be retro fitted to a non heat eco HC.

Ta
Is yours blue or green?

shady lee

962 posts

212 months

Tuesday 31st July 2018
quotequote all
Blue, the latest eco model.

It's the link one that can talk to various sensors etc.

Bullet-Proof_Biscuit

1,058 posts

107 months

Tuesday 31st July 2018
quotequote all
Do they have wall mounted isolator eg like a single gang flush mounted light switch type affair?

These could be swapped for a switch with more 'brains' eg with timer function for off in day on at night or vice versa

dhutch

17,887 posts

227 months

Tuesday 31st July 2018
quotequote all
Photos?

robemcdonald

10,037 posts

226 months

Tuesday 31st July 2018
quotequote all
shady lee said:
Blue, the latest eco model.

It's the link one that can talk to various sensors etc.
I’m at the factory on Thursday. I’ll ask if it’s possible and see if there is a spare heater kicking around somewhere.

shady lee

962 posts

212 months

Tuesday 31st July 2018
quotequote all
robemcdonald said:
I’m at the factory on Thursday. I’ll ask if it’s possible and see if there is a spare heater kicking around somewhere.
Wow, cheers mate!

Much appreciated for having a look.

robemcdonald

10,037 posts

226 months

Wednesday 1st August 2018
quotequote all
Bad news I’m afraid. The heater can not be retrofitted.

That’s the official line at least.. I’ll ask product development on tomorrow.

Thanks

Rob

dhutch

17,887 posts

227 months

Wednesday 1st August 2018
quotequote all
My parents house (late 80's self-build) has a MHRV system, aka, bottom right picture.

Bloody awesome thing, pair of centrifugal fans and a heat exchanger in a box in the attic, and ducting to each room to either remove stale air (bathrooms, shower rooms, kitchen) or blow in fresh preheated air (bedrooms and living rooms).

Cant hear it running standing by the vents, or directly under it on the hall, at normal running speed. Yet you never have to open a window (no trickle vents) and washing dries overnight. No mould, nothing.

Obviously a sod to retro-fit the duct work to a whole house, but we retro fitted the same to my grand parents bunglow in a weekend so doing the first floor would be easy and a good start.

Seriously considering it on our new house (edwardian semi) just for the feel of the house. Nether house are likely air tight enough to demand it, but it saves having issues with towels not drying and mould behind wardrobes.

Dont know what the running costs are but the fans are only just ticking over. After almost 30 years they bearings starting sounding a little grumbly but the manufacture still exists and where able to provide a replacement pair which only needed mild modifications to cowling mounts to fit like for like.

Unit is a 'Villavent' .

Daniel

robemcdonald

10,037 posts

226 months

Wednesday 1st August 2018
quotequote all
30 years old, must have been one of the first MVHRs.

The most modern ones are even better, run even more quietly and have heat exchangers that are up to 90% efficient.
The reduction in heating bills more than pay the fan running costs.

Virtually all new apartments being built now have one.