House built in 2016 - No loft insulation?
House built in 2016 - No loft insulation?
Author
Discussion

DriveWrench

Original Poster:

424 posts

169 months

Thursday 6th February 2025
quotequote all
The initial message was deleted from this topic on 11 August 2025 at 14:40

Super Slo Mo

5,374 posts

229 months

Thursday 6th February 2025
quotequote all
Might be a warm roof, where the insulation panels are on top of the rafters. Or maybe there's insulation between them. Short of removing OSB or lifting tiles, it's difficult to tell.

Ed.Neumann

1,354 posts

39 months

Thursday 6th February 2025
quotequote all
If it is not absolutely freezing up there with our current weather there must be some insulation behind the OSB.

I would imagine it is simply a warm roof design?


Promised Land

5,426 posts

240 months

Thursday 6th February 2025
quotequote all
No Redrow plot I’ve been on has had a warm roof on a 2 1/2 storey plot, but that’s not saying it exists.

Hard to judge but from the pic it looks like 2 sheets of plasterboard on the underside of the ceiling rafters so around 2.4m to the gable, no trusses so I’m guessing your roof is a cassette built roof, panels dropped on with crane rather than a cut roof or top hats which is usually the case on attic trusses if the height is more than a hgv can carry to site.

OSB board is for bracing on attic truss roofs, you could drill a hole with a hole saw somewhere in it to determine celotex behind but to get a CML it surely would have been checked at pre plaster stage for insulation.

If it has celotex behind the OSB above ceiling rafters there is no need to insulate your rafters, you could if you wanted too though.

In the 2 voids either side lower down you’ll have insulation on the first floor ceiling level but also you might have it in the top floor uprights, it depends as we used to insulate from wall plate up on the rafter pitch but regs do get altered.

If that gable is a party wall with a neighbour chances are that’s a spandrel panel, ie a timber truss with double layer plasterboards on either side.

Edited by Promised Land on Thursday 6th February 11:32

bobtail4x4

4,463 posts

140 months

Thursday 6th February 2025
quotequote all
Promised Land said:
No Redrow plot I’ve been on has had a warm roof on a 2 1/2 storey plot, but that’s not saying it exists.

you could drill a hole with a hole saw somewhere in it to determine celotex behind but to get a CML it surely would have been checked at pre plaster stage for insulation.



Edited by Promised Land on Thursday 6th February 11:32
dont Redrow use their own pet BCO?, they probably didnt inspect it??

smokey mow

1,418 posts

231 months

Thursday 6th February 2025
quotequote all
As already said it’s possibly a warm roof. Easiest way to tell would be to drill a small hole (10mm) in the osb and you’ll then find out whether there’s PIR insulation or an empty void behind it.

cadmunkey

800 posts

120 months

Thursday 6th February 2025
quotequote all
Promised Land said:
No Redrow plot I’ve been on has had a warm roof on a 2 1/2 storey plot, but that’s not saying it exists.

Hard to judge but from the pic it looks like 2 sheets of plasterboard on the underside of the ceiling rafters so around 2.4m to the gable, no trusses so I’m guessing your roof is a cassette built roof, panels dropped on with crane rather than a cut roof or top hats which is usually the case on attic trusses if the height is more than a hgv can carry to site.
It certainly looks like a cassette built roof. Would be a standard plasterboard finish if it were any other warm roof construction.

Ed.Neumann

1,354 posts

39 months

Thursday 6th February 2025
quotequote all
Drive wrench, this is a cassette roof, which can be a warm roof if the cassette have insulation in them...

https://pasquill.co.uk/roof-solutions/roof-cassett...



SteBrown91

3,173 posts

160 months

Thursday 6th February 2025
quotequote all
You are still stopping airflow there IMO. There might be an air gap but it wouldn’t flow freely

What I would do if height is at a premium is to fit 50/60mm square lengths of wood across the joists then lay the boards on top of that. It doesn’t take too much of height but raises the boards so there is a bit of flow underneath. I had to do similar in the centre section in my loft due to the extreme low pitch. I used the full loft legs at each end then the above method in the centre around the loft hatch.

EDIT: I would also leave a decent gap around the edge to also promote airflow



Edited by SteBrown91 on Thursday 6th February 19:36

TA14

14,334 posts

289 months

Thursday 6th February 2025
quotequote all
DriveWrench said:
Righto guys - I think I'm going to err on the side of caution and just put some insulation down before putting the boards up. I don't have any heat loss issues in the room below (in fact, it's one of the warmest in the house), but for the sake of £100 or so, it's probably worth doing.

However, the height of the current floor joists are 170mm and I've read that 270mm is now the regulation height required on new builds. As I don't have any issues with heat loss as it is, would it introduce any problems with damp (etc) if I put 150mm of insulation down (leaving a 20mm gap for airflow) and putting loft boards directly on top of the joists? I'm keen to avoid adding any risers as the space in there is tight as it is, especially if it may not be required anyway.

There is also two areas on either side of the loft which wouldn't be boarded, so wondering if I can keep these as is. The sloped roof meets the floor and there is no gap (if that makes a difference).

Rather than send another poor photo (no ladder to get up there easily) I have done a semi-accurate model of what I'm thinking.



If you feel that way why not just use 100mm rockwool and 19mm boarding?

Mr Whippy

32,453 posts

272 months

Thursday 6th February 2025
quotequote all
I’d just board it and leave a 20cm gap at each end for air circulation.

Insulation won’t do anything that’s equal to the cost/faff if the outer roof is already insulated.

Ed.Neumann

1,354 posts

39 months

Friday 7th February 2025
quotequote all
I would just board it, it is a warm roof by the looks of things, the gap between the ceiling and the boards you lay will be more than enough extra insulation. Having a bit of heat going into your storage area is not a bad thing at all imho.

Baldchap

9,639 posts

123 months

Friday 7th February 2025
quotequote all
If it's warm up there then I can 100% guarantee it's insulated above the OSB.

At this time of year, uninsulated roofs are COLD!!!

wolfracesonic

9,313 posts

158 months

Friday 7th February 2025
quotequote all
There are others on here more qualified to comment but wouldn’t installing rafter level insulation AND having a warm cassette roof create a crude hybrid roof, with possible condensation issues on the underside of the OSB?

Stegel

2,087 posts

205 months

Friday 7th February 2025
quotequote all
As Wolfracesonic indicates, insulating at ceiling level will cause issues. If, as looks to be the case, it’s a warm roof the black material you can see through to around the OSB will be a plastic vapour barrier (Celotex and similar most frequently have a silver foil face). This stops water vapour entering the construction and condensing in the colder layers of the build-up (interstitial condensation).

By insulating the void at horizontal ceiling level you are making the void above a cold roof - a traditional loft space I suppose. Not a problem, but a cold roof must be ventilated to deal with the water vapour that will inevitably penetrate into the void. Arranging this would be a massive headache, but more importantly would render the insulation in the warm roof structure redundant - you would be inviting the outside air to come inside the warm roof structure.

I would board the void without any additional insulation and then everything remains within the warm roof envelope and untroubled by condensation worries.

sospan

2,755 posts

253 months

Friday 7th February 2025
quotequote all
Do the drill a small check first. That will give you a starting scenario.
Also check the temperature in the loft for added info. Then decide on your options.

sospan

2,755 posts

253 months

Friday 7th February 2025
quotequote all
Do the drill a small check first. That will give you a starting scenario.
Also check the temperature in the loft for added info. Then decide on your options.