What am I doing wrong
Author
Discussion

dba7108

Original Poster:

738 posts

198 months

Saturday 6th September 2025
quotequote all
I had a ring doorbell transformer and it went bang the other day when I moved it. Been working for 4 years fine. It's wired in to a 13amp plug. I bought a new transfer today same one. Wired it up and it's gone bang. The plug has a 5amp fuse. The previous plug had I think a 13amp fuse. What's going on here. It previously worked for years and now it's not!


Simpo Two

92,955 posts

295 months

Saturday 6th September 2025
quotequote all
Are those wires being gripped properly?

Fore Left

1,618 posts

212 months

Saturday 6th September 2025
quotequote all
How do you know the transformer has gone 'bang? What have you tested to confirm it?

Doofus

34,548 posts

203 months

Saturday 6th September 2025
quotequote all
Curiously, as per a thread I made on here a while ago, my Ring was AC, but your transformer says DC. Is it the right transformer for the particular model of doorbell?

OIC

592 posts

23 months

Saturday 6th September 2025
quotequote all
All the makings of a suicide plug right there.

For it be.

hidetheelephants

36,179 posts

223 months

Saturday 6th September 2025
quotequote all
If it's gone bang it's the load that's caused it, not the plug.

dba7108

Original Poster:

738 posts

198 months

Sunday 7th September 2025
quotequote all
Fore Left said:
How do you know the transformer has gone 'bang? What have you tested to confirm it?
I turned it on to test it and a spark and bang happened!

GasEngineer

2,335 posts

92 months

Sunday 7th September 2025
quotequote all
dba7108 said:
Fore Left said:
How do you know the transformer has gone 'bang? What have you tested to confirm it?
I turned it on to test it and a spark and bang happened!
Did you have the output side of the transformer connected when you energised it?

No ideas for a name

3,279 posts

116 months

Sunday 7th September 2025
quotequote all
dba7108 said:
I had a ring doorbell transformer and it went bang the other day when I moved it. Been working for 4 years fine. It's wired in to a 13amp plug. I bought a new transfer today same one. Wired it up and it's gone bang. The plug has a 5amp fuse. The previous plug had I think a 13amp fuse.
Depends how much test kit you have...

Did you move the plug and transformer to a new mains outlet?
If so, I am suspecting that outlet (since that is the only change) - though at first thought I can't see why.

1) At the transformer end of you death lead, do you have 230VAC across L&N (when plugged in to your new location)?
2) Same voltage when moved back to the original location?
3) Is the fuse intact?
4) L&N reversed on the new outlet (shouldn't make any difference if it is a transformer - but it bay be some 'electronic transformer substitute' which might not be happy?