Overflow pipe drilled through DPC
Discussion
The previous owner of our house had a water softener installed, and I’ve only just twigged that the installer most likely drilled through the DPC to fit the overflow. See below. The exterior DPC sits just above the air brick.

I believe we have a stepped DPC/cavity trays (I asked here previously about water splashing my walls and was told as much) so presumably this pipe goes straight through it.
I haven’t noticed any damp issues because of this, but how much of a big deal is this, and should I do anything about it?
I believe we have a stepped DPC/cavity trays (I asked here previously about water splashing my walls and was told as much) so presumably this pipe goes straight through it.
I haven’t noticed any damp issues because of this, but how much of a big deal is this, and should I do anything about it?
You should have a cavity tray installed above the air brick so yes it will have been drilled through to fit the pipe.
The purpose of the cavity tray is to deflect any moisture and condensation in the cavity to the outside and prevent it from pooling on the top of the air brick where it could then soak to the inside blockwork.
What they’ve done is wrong but if you’ve not noticed any issues then it’s likely not going to be a problem.
The purpose of the cavity tray is to deflect any moisture and condensation in the cavity to the outside and prevent it from pooling on the top of the air brick where it could then soak to the inside blockwork.
What they’ve done is wrong but if you’ve not noticed any issues then it’s likely not going to be a problem.