Crack in kitchen floor of prospective house purchase
Discussion
Skyedriver said:
Hi, when was the house built?
Red shale fill under floors was common practice for a while until they realised it reacted with the ground water and (generally) expanded.
There's only one cure.
You’d see classic heave to the floor and brickwork pushed out externally below dpcRed shale fill under floors was common practice for a while until they realised it reacted with the ground water and (generally) expanded.
There's only one cure.
DSLiverpool said:
It s an old cottage now Frankensteins monster! Beautifully done but I ll use a good surveyor
Little cracks aren’t unusual in houses that have been built in lots of stages. Our place has had at least four main developments over almost two centuries; putting something new in next to old needs time to settle down and if you can’t wait a couple of years before continuing you can get cosmetic marks like that.
mikees said:
Under floor heating over heat? The right hand bottom crack looks a bit to straight to be structural . Maybe. I think you d have to have the floor up. Are the sellers not worried or forth coming?
There is a radiator in the picture so would be odd to have both underfloor heating and a radiator. What ever the cause those tiles needs lifting and replacing, £30-50/sqm for new tiles, same again for labour, that's a reasonable amount to negotiate off the price.Steve H said:
Our place has had at least four main developments over almost two centuries; putting something new in next to old needs time to settle down and if you can t wait a couple of years before continuing you can get cosmetic marks like that.
Those cracks are more than cosmetic, surely you need to replace those tiles.gangzoom said:
There is a radiator in the picture so would be odd to have both underfloor heating and a radiator. What ever the cause those tiles needs lifting and replacing, £30-50/sqm for new tiles, same again for labour, that's a reasonable amount to negotiate off the price.
USA couple going home so lots of potential inc a John Deer tractor mower :-)gangzoom said:
Steve H said:
Our place has had at least four main developments over almost two centuries; putting something new in next to old needs time to settle down and if you can t wait a couple of years before continuing you can get cosmetic marks like that.
Those cracks are more than cosmetic, surely you need to replace those tiles.Our kitchen underfloor was zoned due to the size of the breakfast area. They claimed it wouldn’t crack, but it did. Happened in first 3 months and hasn’t moved since.
Could chip the flooring up and lay a floating floor onto it. But the concrete slab has probably done all
It’s moving now and you could tile over again with no issues ?
Could chip the flooring up and lay a floating floor onto it. But the concrete slab has probably done all
It’s moving now and you could tile over again with no issues ?
That can happen with the substrate isn't "sound" - i.e. hardboard underneath or similar and wasnt nailed down well enough. I know this because I did it with Travertine in my last place. Laid it down on hardboard that was already there - thought I'd nailed it down well, but after about 3 or 4 years long cracks like those started to appear.