Have recently moved into a terraced property.

Fairly new combi Worcestor boiler. Works fine. Needed a bit of pressure when I moved in, but found out how to do it and sorted that.

But have noticed it sort of activates every half hour or so for a few seconds then stops, is this normal? I presume so.

Is this necessary, is it switch on/off able? Also, if I go away is it worth turning the boiler off completely to save electricity? Can that cause issues?

.:ian:.

3,076 posts

232 months

Yesterday (17:30)
quotequote all
Does it trigger when something like the dishwasher/washing machine/toilet cistern, specifically when the valve closes?

If so this is water hammer triggering the hot water flow valve.

Lincsls1

4,068 posts

169 months

Yesterday (17:35)
quotequote all
bergclimber34 said:
Have recently moved into a terraced property.

Fairly new combi Worcestor boiler. Works fine. Needed a bit of pressure when I moved in, but found out how to do it and sorted that.

But have noticed it sort of activates every half hour or so for a few seconds then stops, is this normal? I presume so.

Is this necessary, is it switch on/off able? Also, if I go away is it worth turning the boiler off completely to save electricity? Can that cause issues?
Highly likely it has the 'pre-heat' function turned on.
Once you've identified the exact model, a quick Google or youtube search will show you how to turn it off.
You're looking to put it into 'ECO' mode.
This function has no effect on the heating, it is purely a hot water function, 'pre-heat' is suppose to reduce the delay to the hot tap.

Rough101

3,056 posts

104 months

Yesterday (19:26)
quotequote all
Lincsls1 said:
Highly likely it has the 'pre-heat' function turned on.
Once you've identified the exact model, a quick Google or youtube search will show you how to turn it off.
You're looking to put it into 'ECO' mode.
This function has no effect on the heating, it is purely a hot water function, 'pre-heat' is suppose to reduce the delay to the hot tap.
This, unless it’s in Eco mode it will cycle to reduce the time for hot water.

bergclimber34

Original Poster:

3,951 posts

22 months

It does not trigger when anything is used no, yes at times it will trigger if I use the hot water tap, that makes sense.

It does have ECO mode, but I have to work out how to turn off this pre heat thing I think

It sort of activates every half hour or so, without anything being used. Like a cycle almost

Mike Legerwood

93 posts

4 months

bergclimber34 said:
It does not trigger when anything is used no, yes at times it will trigger if I use the hot water tap, that makes sense.

It does have ECO mode, but I have to work out how to turn off this pre heat thing I think

It sort of activates every half hour or so, without anything being used. Like a cycle almost
It's doing a little pre-heat of the hot water heat exchanger in the boiler every 30 mins or so, with the idea that when you turn on a tap it gives you hot water quicker.

To turn this off you press and light the ECO button. Doesn't really make much difference to the speed of hot water delivery.

(It would be a lot clearer if it just said "Pre Heat Off", rather than turning something on to turn something off !)

Lincsls1

4,068 posts

169 months

If you take a picture of the boiler I will tell you how to do it.

bergclimber34

Original Poster:

3,951 posts

22 months

Ok chaps

pre heat was on, this I suppose is the little cycle a few of you mentioned, I have turned it off.

Will also investigate Eco mode

Thanks again fellas and fellettes maybe!!

Lincsls1

4,068 posts

169 months

bergclimber34 said:
Ok chaps

pre heat was on, this I suppose is the little cycle a few of you mentioned, I have turned it off.

Will also investigate Eco mode

Thanks again fellas and fellettes maybe!!
If you have turned 'pre-heat' off, then that action is turning 'ECO' mode on. It's just a toggle between the two. It is one or the other.

bergclimber34

Original Poster:

3,951 posts

22 months

Yes, It was turned on, and since has stopped the start up every half hour or so.

Mike Legerwood

93 posts

4 months

bergclimber34 said:
Ok chaps

pre heat was on, this I suppose is the little cycle a few of you mentioned, I have turned it off.

Will also investigate Eco mode

Thanks again fellas and fellettes maybe!!
To clarify : ECO mode (light on) means pre heat off. As I mentioned it would be a lot clearer if the button actually said pre heat off!

bergclimber34

Original Poster:

3,951 posts

22 months

It would, my old boiler had that, this one just says as you say pre heat on of off.

As I say, this place is a gem for little things like this. Thanks