locating a shower pump
Discussion
I'm just about to fit a power shower pump to replace a pathetic electric shower but the shower room is tiny and don;t really want to put the pump in the airing cupboard (As I've done before) as it's the new born's bedroom and don;t want to wake him when it comes on.
Can I locate a gravity feed pump next to the cold water header tank (that feeds the Hot Water cylindar)? and take another feed directly off the tank to feed the cold on the shower?
I can pipe directly through the attic space to the shower room then and keeps the pump noise as far away as possible....
Will pulling the hot all the way to the loft space, near elvel with the header tank to then go back down to the shower be an issue?
Thanks,
Virgil
Can I locate a gravity feed pump next to the cold water header tank (that feeds the Hot Water cylindar)? and take another feed directly off the tank to feed the cold on the shower?
I can pipe directly through the attic space to the shower room then and keeps the pump noise as far away as possible....
Will pulling the hot all the way to the loft space, near elvel with the header tank to then go back down to the shower be an issue?
Thanks,
Virgil
Look into Aqualisa Quartz or Visage pumped shower units - the whole thing goes in the loft above the bathroom & just drops down the wall. Ideal if you have an existing bathroom & don't want to dig holes in the tiles etc. Maybe not appropriate if you already have plumbing in place though but presumably you only have a cold feed to your electric shower?
There are different versions of each depending on what the situation is i.e. suitable for combi boilers or tanked systems & where you have existing plumbing or where there is none. The one I used is what was called a "pumped, exposed" unit i.e. there is a pump unit in the loft & a single pipe comes down the wall & the whole thing surface mounts.
There are different versions of each depending on what the situation is i.e. suitable for combi boilers or tanked systems & where you have existing plumbing or where there is none. The one I used is what was called a "pumped, exposed" unit i.e. there is a pump unit in the loft & a single pipe comes down the wall & the whole thing surface mounts.
Edited by IainZ on Friday 3rd December 17:01
Have a look here:
http://www.salamanderpumps.co.uk/Download/instruct...
If it's in the loft you may get the pump sucking air down the vent pipe rather than from the hot cylinder..... or you may not. Have a look at the link, it describes the ideal fitting for various pumps. Next to the cold water tank may not have enough head but a negaitive pressure pump would sort that. Freezing could bugger the pump so in a warm area is best, next to the cylinder is best of all.
I had a problem with pumps in the loft recently so I did a lot of reading. Next to the cylinder sorted it.
http://www.salamanderpumps.co.uk/Download/instruct...
If it's in the loft you may get the pump sucking air down the vent pipe rather than from the hot cylinder..... or you may not. Have a look at the link, it describes the ideal fitting for various pumps. Next to the cold water tank may not have enough head but a negaitive pressure pump would sort that. Freezing could bugger the pump so in a warm area is best, next to the cylinder is best of all.
I had a problem with pumps in the loft recently so I did a lot of reading. Next to the cylinder sorted it.
ferg said:
I would never put a shower pump in the loft.
They need VENTILATION and LAGGING.
Go figure!!!
Indeed! However in my case (Aqualisa) the loft was suggested as a suitable location. The instructions say you mustn't cover it, but then it freezes. So based on the premise that I only use the shower for 2-3 minutes a day and I reckon it can't possibly overheat in that time, I tucked an old sleeping bag over it. And the shower worked this morning They need VENTILATION and LAGGING.
Go figure!!!


Simpo Two said:
ferg said:
I would never put a shower pump in the loft.
They need VENTILATION and LAGGING.
Go figure!!!
Indeed! However in my case (Aqualisa) the loft was suggested as a suitable location. The instructions say you mustn't cover it, but then it freezes. So based on the premise that I only use the shower for 2-3 minutes a day and I reckon it can't possibly overheat in that time, I tucked an old sleeping bag over it. And the shower worked this morning They need VENTILATION and LAGGING.
Go figure!!!


Gassing Station | Homes, Gardens and DIY | Top of Page | What's New | My Stuff