On an electricity pole in a field the Peak District. First thought was some sort of fuse, but there is no electrical connection that I could see, and nothing similar on any of the other nearby poles.

I’d guess it’s about 9” tall, and would need a ladder to reach it.



Edit - damn photo! Green end is at the bottom....

Initforthemoney

743 posts

174 months

Sunday 25th August 2019
quotequote all
Alien detector.

HTH.

595Heaven

Original Poster:

3,370 posts

108 months

Sunday 25th August 2019
quotequote all
That was my guess as well!

Bit of a waste of time having it this afternoon, as we had a fly past from a Lancaster that would scare the bejeezus out of any pesky aliens...

finlo

4,453 posts

233 months

Sunday 25th August 2019
quotequote all
Isn't it one of those air quality measuring devices?

JonChalk

6,469 posts

140 months

Sunday 25th August 2019
quotequote all
finlo said:
Isn't it one of those air quality measuring devices?
I was going suggest the same.

Something like a Draeger tube - measures specific chemicals / elements by absorption in another material - doesn't need any power.

Probably up for a fixed time, then taken down and analysed?

595Heaven

Original Poster:

3,370 posts

108 months

Sunday 25th August 2019
quotequote all
Thanks! Sounds the most plausible answer

x type

1,020 posts

220 months

Sunday 25th August 2019
quotequote all
It is in fact an FPI better known as
Fault passage indicator

these were fitted to poles spaced at lets say every 25 - 30 poles on the high voltage system (11,000 volts)

the idea was if there was a fault on the overhead power lines these gizzmos would detect it and start to flash if the fault was past it

Where I worked people living in site of them were asked if the power went off would they look to see if it was flashing and call a dedicated phone line to report it .

If they did we knew to look past that one and check the next one etc. to narrow down the fault location

Good idea but never ever worked !


Johnnytheboy

24,499 posts

216 months

Sunday 25th August 2019
quotequote all
x type said:
lets say every 25 - 30 poles on the high voltage system (11,000 volts)
OK...



"Every 25-30 poles on the high voltage system (11,000 volts)"

JonChalk

6,469 posts

140 months

Sunday 25th August 2019
quotequote all
Ah right.

Googled it.

Weird.

Like these: http://www.nortroll.no/products/linetroll/linetrol... ?

How the hell do they work? Do they just wait for a massive change in field strength to indicate loss of current in cables above?

Tom _M

451 posts

100 months

Sunday 25th August 2019
quotequote all
Johnnytheboy said:
x type said:
lets say every 25 - 30 poles on the high voltage system (11,000 volts)
OK...



"Every 25-30 poles on the high voltage system (11,000 volts)"
Very good smile

FN2TypeR

7,091 posts

123 months

Sunday 25th August 2019
quotequote all
They detect changes in the magnetic field around the cable, if there's an fault and additional current flowing through the line then they'll activate

595Heaven

Original Poster:

3,370 posts

108 months

Monday 26th August 2019
quotequote all
x type said:
It is in fact an FPI better known as
Fault passage indicator

these were fitted to poles spaced at lets say every 25 - 30 poles on the high voltage system (11,000 volts)

the idea was if there was a fault on the overhead power lines these gizzmos would detect it and start to flash if the fault was past it
JonChalk said:
Ah right.

Googled it.

Weird.

Like these: http://www.nortroll.no/products/linetroll/linetrol... ?

How the hell do they work? Do they just wait for a massive change in field strength to indicate loss of current in cables above?
Many thanks both! Never noticed anything like it before. It is on a pole does a very narrow lane with hardly any houses or traffic, so maybe it was to allow for quick drive by fault checking.

Will now be looking out for these all the time!

595Heaven

Original Poster:

3,370 posts

108 months

Monday 26th August 2019
quotequote all
Got a bit closer this morning rolleyes




talksthetorque

10,821 posts

165 months

Monday 26th August 2019
quotequote all
Still not managed to get it the right way up though?biggrin


Jakarta

583 posts

172 months

Monday 26th August 2019
quotequote all
595Heaven said:
Got a bit closer this morning rolleyes
Fishing reel holder

595Heaven

Original Poster:

3,370 posts

108 months

Monday 26th August 2019
quotequote all
talksthetorque said:
Still not managed to get it the right way up though?biggrin
Nope... Thanks!

davhill

5,263 posts

214 months

Friday 30th August 2019
quotequote all
anonymous said:
[redacted]
Nah, it's a distress flare in case the pole gets in bother,

Genuine bedouin.

CrunkleFloop

781 posts

275 months

Friday 30th August 2019
quotequote all
scratchchin

Looks like Aliens did decide to pass through Lancaster after all.