Bloody ebayers! Can anyone spot basic error in this spec?
Bloody ebayers! Can anyone spot basic error in this spec?
Author
Discussion

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
OK. Am looking for a high power inverter for a boat.
This is the spec of the one I've found.

Electrical Specifications

Max. Continuous Power 3000 watts

Peak Power 6000 watts

AC output voltage 240VAC

AC output frequency 50Hz+5%

AC output waveform Modified Sine Wave

DC input voltage 12V DC

voltage range 10~15VDC

No Land Current Draw <0.8 amps(at 12V input)

LED Indicator Input voltage level, output load level and status

Efficiency (Typ.) >80%

Fuse (12V) 30A *12 (12V)

Bat. Low Alarm 10.5VDC

Bat. Low Shutdown 10.0VDC

Over Load Shut off output voltage, re-power on to recover

Over Voltage 15-16VDC

Cooling Loading controlled cooling fan


Can you see an obvious problem here?

I've had a to-and-fro Q&A session with the seller, will post these up later!

Justayellowbadge

37,057 posts

273 months

Wednesday 24th November 2010
quotequote all
When Will has created a 'Good God, it could not possibly be more boring and geeky' forum, I'll be glad to move this for you, chap.

Edited by Justayellowbadge on Wednesday 24th November 15:13

Ali_D

1,115 posts

315 months

Wednesday 24th November 2010
quotequote all
Justayellowbadge said:
When Will has created a 'God Good, it could not possibly be more boring and geeky' forum, I'll be glad to move this for you, chap.
Having just looked at the Sean Connery thread this is all the more appreciated! biggrin

TheEnd

15,370 posts

219 months

Wednesday 24th November 2010
quotequote all
Is this going to involve fuses?

zollburgers

1,285 posts

214 months

Wednesday 24th November 2010
quotequote all
30A at 12v is way less than 3kW?

SplatSpeed

7,491 posts

282 months

Wednesday 24th November 2010
quotequote all
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't

sleep envy

62,260 posts

280 months

Wednesday 24th November 2010
quotequote all
shout Neil Bolton, your thread has arrived

Fume troll

4,389 posts

243 months

Wednesday 24th November 2010
quotequote all
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.

y2blade

56,325 posts

246 months

Wednesday 24th November 2010
quotequote all
walk in....look around....walk out

dreamz

5,299 posts

224 months

Wednesday 24th November 2010
quotequote all
  • kick tyres*
hmmmmm.

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
zollburgers said:
30A at 12v is way less than 3kW?
It's not just me then!

First question to customer:- If this unit is 3kW why is the input fuse only 30A?
Response :- Pls google 1amp = watts the answer is there

Second question to customer:- That's what I thought. If the fuse is in the 12V circuit (as stated) 30A x 12 V =360W. This does not take into account the efficiency of the unit!
Response :- 30a x 12v = 3600watts. 1amp = 120 watts

I may not be buying this particular unit! confused


SplatSpeed

7,491 posts

282 months

Wednesday 24th November 2010
quotequote all
Poledriver said:
zollburgers said:
30A at 12v is way less than 3kW?
It's not just me then!

First question to customer:- If this unit is 3kW why is the input fuse only 30A?
Response :- Pls google 1amp = watts the answer is there

Second question to customer:- That's what I thought. If the fuse is in the 12V circuit (as stated) 30A x 12 V =360W. This does not take into account the efficiency of the unit!
Response :- 30a x 12v = 3600watts. 1amp = 120 watts

I may not be buying this particular unit! confused
yes it does 833.3% efficent

i would buy it if it is that efficent!

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.
I can't believe this... The unit does actually have 12 fuses!! Unreal, but would probably work better than one big one!
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.

I've never seen it done that way before, but it is valid! scratchchin

I stand Sit corrected!
getmecoat

Mazdarese

21,403 posts

218 months

Wednesday 24th November 2010
quotequote all
Is this thread foreign?

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
Mazdarese said:
Is this thread foreign?
Niet!

SplatSpeed

7,491 posts

282 months

Wednesday 24th November 2010
quotequote all
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.
I can't believe this... The unit does actually have 12 fuses!! Unreal, but would probably work better than one big one!
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.

I've never seen it done that way before, but it is valid! scratchchin

I stand Sit corrected!
getmecoat
as a fuse starts to heat its resistance increases creating a feedback cooling the fuse. the fuses should balance themselves as any one fuse getting hot will have reduced currant.

Justayellowbadge

37,057 posts

273 months

Wednesday 24th November 2010
quotequote all
SplatSpeed said:
as a fuse starts to heat its resistance increases creating a feedback cooling the fuse. the fuses should balance themselves as any one fuse getting hot will have reduced currant.
Thanks for explaining that, I knew it happened but not the raisin.

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.
I can't believe this... The unit does actually have 12 fuses!! Unreal, but would probably work better than one big one!
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.

I've never seen it done that way before, but it is valid! scratchchin

I stand Sit corrected!
getmecoat
as a fuse starts to heat its resistance increases creating a feedback cooling the fuse. the fuses should balance themselves as any one fuse getting hot will have reduced currant.
With the amount of current required to blow the fuses I should think it'll be quite a rapid process!

SplatSpeed

7,491 posts

282 months

Wednesday 24th November 2010
quotequote all
Poledriver said:
SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.
I can't believe this... The unit does actually have 12 fuses!! Unreal, but would probably work better than one big one!
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.

I've never seen it done that way before, but it is valid! scratchchin

I stand Sit corrected!
getmecoat
as a fuse starts to heat its resistance increases creating a feedback cooling the fuse. the fuses should balance themselves as any one fuse getting hot will have reduced currant.
With the amount of current required to blow the fuses I should think it'll be quite a rapid process!
ahh the beauty of negative feedback, something inherently unstable can be made stable with negative feedback, ie F117A, op amps and the like

Poledriver

Original Poster:

29,627 posts

225 months

Wednesday 24th November 2010
quotequote all
SplatSpeed said:
Poledriver said:
SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain't
There's 12 fuses, should be fine.

Cheers,

FT.
I can't believe this... The unit does actually have 12 fuses!! Unreal, but would probably work better than one big one!
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.

I've never seen it done that way before, but it is valid! scratchchin

I stand Sit corrected!
getmecoat
as a fuse starts to heat its resistance increases creating a feedback cooling the fuse. the fuses should balance themselves as any one fuse getting hot will have reduced currant.
With the amount of current required to blow the fuses I should think it'll be quite a rapid process!
ahh the beauty of negative feedback, something inherently unstable can be made stable with negative feedback, ie F117A, op amps and the like
If you knew how many large mixing desks I've worked on over the years you would be able to imagine how much I am nodding now! smile