Need to wire up a Security Light to a switch (its the non sensor type). Doing the switch to light bit is ok, but it's finding the feed for the switch. I once saw someone take a feed from a socket, is this ok? Run the live through the switch, run the negative straight through and the earth through the appropriate?
Oh, and while I'm at it, I'm trying to wire up a normal light in a cupboard. Have run the feed wire to another switch in an attempt to run a spur, but there isn't a negative, any ideas?
Cheers
Stuart.
Oh, and while I'm at it, I'm trying to wire up a normal light in a cupboard. Have run the feed wire to another switch in an attempt to run a spur, but there isn't a negative, any ideas?
Cheers
Stuart.
The best way to do this is to get a fused switch. You can then take the feed from the ring main via a socket and fuse at the switch appropriate to the lamp.
For the cupboard lamp, yes you often find that neg feed is not returned to the switch. No need, the switch is like you describe for the outside lamp. Only the live passes through the switch. More dificult this one, it rather depends on where the nearest source is, usually a lamp rose. Otherwise you could do it with another fused switch thereby allowing the feed to come from a socket
>> Edited by tvrbob on Saturday 12th April 16:35
For the cupboard lamp, yes you often find that neg feed is not returned to the switch. No need, the switch is like you describe for the outside lamp. Only the live passes through the switch. More dificult this one, it rather depends on where the nearest source is, usually a lamp rose. Otherwise you could do it with another fused switch thereby allowing the feed to come from a socket
>> Edited by tvrbob on Saturday 12th April 16:35
I've done that before ahem.
I have thought of that, but this is only temporary for the next 6 or so months until I get the wiring for my Garage put in, I'm having a RCD Consumer Unit put in a Little 'Coal Bunker' style cubby hole under the house which will feed the consumer unit in my garage, the House wall lights, the cupboard light previously mentioned and the garden lighting.
Bob,
Thanks for the reply, you pretty much confirmed what I thought!
The cupboard light will be a bugger, the nearest Socket is the other side of a door, and the nearest rose is pretty much inaccesible for the purposes of running wires.
Although, as I just mentioned, it's a temporary thing, so a bit of trunking here and there won't be too bad!
Thanks for the reply, you pretty much confirmed what I thought!
The cupboard light will be a bugger, the nearest Socket is the other side of a door, and the nearest rose is pretty much inaccesible for the purposes of running wires.
Although, as I just mentioned, it's a temporary thing, so a bit of trunking here and there won't be too bad!
wedg1e said: The only dodgy bit with running a light spur from a socket ring is that you (or someone else) at some point in the future may well assume that the light is fed from the circuit breaker/ fuse marked 'Lights' and kill the wrong circuit...![]()
Ian
Get one of those screwdrivers that tells you if a wire is live. About 80p from B&Q