Fire Extinguisher Mount
Fire Extinguisher Mount
Author
Discussion

turnbaugh

Original Poster:

131 posts

269 months

Monday 5th December 2005
quotequote all
Has anyone figured out a good place to mount a fire extinguisher that you can reach while seated?

DerekFSU

45 posts

257 months

Monday 5th December 2005
quotequote all
No pics cause it's in the shop but my guy put it just under the dome light to the right of the driver's shoulder. I think it's the best place within the driver's reach.

turnbaugh

Original Poster:

131 posts

269 months

Monday 5th December 2005
quotequote all
Thought about that but it would have to be a pretty small extinguisher. I think there is only 10 inches of height. What extinguisher are you using? All the 2.5 lb ones seem to be 14 inches high.

kenprotheroe

112 posts

257 months

Monday 5th December 2005
quotequote all
What's wrong with the shelf, inside the rear window

and over the tunnel ? I find it within reach there.

paulcundy

1,897 posts

294 months

Monday 5th December 2005
quotequote all
drivers side pocket? I had a nice one from Halfords that fitted perfectly.

amg merc

11,955 posts

282 months

Monday 5th December 2005
quotequote all
Mine, just ahead of the front seat laterally - two bolt-holes through the floor (silconed from underneath afterwards) - easy to reach without twisting your body to get behind you.

joust

14,622 posts

288 months

Monday 5th December 2005
quotequote all
paulcundy said:
drivers side pocket? I had a nice one from Halfords that fitted perfectly.
That's where mine is.

J

DanH

12,287 posts

289 months

Monday 5th December 2005
quotequote all
paulcundy said:
drivers side pocket? I had a nice one from Halfords that fitted perfectly.


Are there no motorsport regs about how big the extinguisher should be? To fit in the pocket it would need to be pretty small I'd have thought?

paulcundy

1,897 posts

294 months

Monday 5th December 2005
quotequote all
DanH said:
paulcundy said:
drivers side pocket? I had a nice one from Halfords that fitted perfectly.


Are there no motorsport regs about how big the extinguisher should be? To fit in the pocket it would need to be pretty small I'd have thought?


we're not talking motorpsports are we. If we are yes there are a whole host of regs. I thought we were "sensible thing to have close at hand" for road and track driving.
Hmm suppose for track days they are supposed to be screwed down.
Regards
PauL C

m12_nathan

5,138 posts

288 months

Monday 5th December 2005
quotequote all
I have to question the use of a small hand held extinguisher in a Noble, by the time you've noticed a fire and got the rear clam up (assuming most fires will be engine related) it may be too late for a little hand held one? a plumbed one at behind the passenger seat and firing into the engine bay would be a better bet maybe?

DanH

12,287 posts

289 months

Monday 5th December 2005
quotequote all
paulcundy said:
DanH said:
paulcundy said:
drivers side pocket? I had a nice one from Halfords that fitted perfectly.


Are there no motorsport regs about how big the extinguisher should be? To fit in the pocket it would need to be pretty small I'd have thought?


we're not talking motorpsports are we. If we are yes there are a whole host of regs. I thought we were "sensible thing to have close at hand" for road and track driving.
Hmm suppose for track days they are supposed to be screwed down.
Regards
PauL C


I just wasn't sure if it would be any use. The one that came with my car is enormous, and although not plumbed in still makes the little one I used to have in my noble look a bit silly.

amg merc

11,955 posts

282 months

Monday 5th December 2005
quotequote all
m12_nathan said:
I have to question the use of a small hand held extinguisher in a Noble, by the time you've noticed a fire and got the rear clam up (assuming most fires will be engine related) it may be too late for a little hand held one? a plumbed one at behind the passenger seat and firing into the engine bay would be a better bet maybe?


Good point Nathan but the way I look at it the small extinguisher inside my cabin is there more to get me out "unsinged" than to save the car that's insured anyway!

broad

314 posts

256 months

Monday 5th December 2005
quotequote all
There are various regs for motorsport and at different levels. Off the top of my head I can only confirm the rallying requirements and they are, I think, the most stringent. We have to run a minimum of a 2.25 litre mechanically or electrically operated full discharge system and carry a 1.75 litre handheld in the cabin. Discharge of the plumbed system must be able to be achieved by either the occupants or someone outside the car.

I always advise and install a 4 litre electrically operated system with 2 outputs toward electrical and fuel systems and 2 outputs aimed at the driver and co-driver. The electric systems are more reliable, having no T pulls to snap off or cables to get damaged in a heavy impact. They are battery operated and we change this every event.

The manual extinguisher will remain a 1.75 or 2.25 litre affair.

In my opinion those small halfords jobs are only up to putting out say a small electrical fire under the dash. Worthwhile but pretty useless for other firefighting duties.

If this is not for motorsport use I would try and get hold of a halon extinguisher. They've been banned by the FIA for use in motorsports and replaced with AFFF but were far superior at putting out fires than the new stuff.

HTH

Graham

adrian w

15,449 posts

257 months

Monday 5th December 2005
quotequote all
I thought Vegantune did an extinguisher system for the Noble.

DanH

12,287 posts

289 months

Monday 5th December 2005
quotequote all
broad said:
There are various regs for motorsport and at different levels. Off the top of my head I can only confirm the rallying requirements and they are, I think, the most stringent. We have to run a minimum of a 2.25 litre mechanically or electrically operated full discharge system and carry a 1.75 litre handheld in the cabin. Discharge of the plumbed system must be able to be achieved by either the occupants or someone outside the car.

I always advise and install a 4 litre electrically operated system with 2 outputs toward electrical and fuel systems and 2 outputs aimed at the driver and co-driver. The electric systems are more reliable, having no T pulls to snap off or cables to get damaged in a heavy impact. They are battery operated and we change this every event.

The manual extinguisher will remain a 1.75 or 2.25 litre affair.

In my opinion those small halfords jobs are only up to putting out say a small electrical fire under the dash. Worthwhile but pretty useless for other firefighting duties.

If this is not for motorsport use I would try and get hold of a halon extinguisher. They've been banned by the FIA for use in motorsports and replaced with AFFF but were far superior at putting out fires than the new stuff.

HTH

Graham


Why was halon banned? Any side effects we should know about?

GreenV8S

31,014 posts

313 months

Monday 5th December 2005
quotequote all
DanH said:

Why was halon banned? Any side effects we should know about?

It was banned for environmental reasons, it is an ozone depleting gas.

joust

14,622 posts

288 months

Monday 5th December 2005
quotequote all
m12_nathan said:
I have to question the use of a small hand held extinguisher in a Noble, by the time you've noticed a fire and got the rear clam up (assuming most fires will be engine related) it may be too late for a little hand held one? a plumbed one at behind the passenger seat and firing into the engine bay would be a better bet maybe?
Mine is rated to give 40 seconds of continous output which I considered enough as if it's more than that then it's going to be a serious insurance job anyway!

J

alex s

2,105 posts

265 months

Monday 5th December 2005
quotequote all
I had one of the small hand held ones from Halfords, which i used to try to put out a fire that had just started in a MGF at a service station (well she was an attractive lady in need!) the Fire was in the engine bay and it was a complete waste of time. Had very little, if any effect. As was metioned earlier in this thread they are probably only any use for a very small electrical fire.

GreenV8S

31,014 posts

313 months

Monday 5th December 2005
quotequote all
What sort was the hand held? I used a 1.75 AFFF to put out a small oil fire earlier in the year and it was more then enough. The specialist who sold me the replacement recommended dry powder as it has better knock-down properties, but it is a bit more tricky to use and makes a huge mess of carpets etc.

broad

314 posts

256 months

Monday 5th December 2005
quotequote all
I think it really depends on the type of fire with AFFF. A few years back we were welding a cage in a Production Class Impreza and the roof lining caught alight (they had to run with full internal trim including rear seats, carpet etc !!!) Luckily the AFFF handheld was very close by but it was very slow to knock the flames out as we chased them around the roof !!

I know that Milner, Dale and others competing in factory cars on the British Championship() have had total losses because their AFFF were incapable of knocking out innocuous looking fires that took hold. All this despite emptying the entire contents of their extinguishers and those of following competitors and event safety crews.

AFFF - good for the environment, not so good for flames !!!

G