Discussion
could it be that they cut in at different temperatures.
In this doc on page 6 it says Fan 1 above 92°C and Fan 2 at 94°C:
http://www.thetvrsite.com/files/ecu/user-manual-tv...
maybe you could test to see if the fan relay 1 & 7 has a 12V supply to pins 85 & 30/51, if it does not, check fuse 1 , 3 and 20.
In this doc on page 6 it says Fan 1 above 92°C and Fan 2 at 94°C:
http://www.thetvrsite.com/files/ecu/user-manual-tv...
maybe you could test to see if the fan relay 1 & 7 has a 12V supply to pins 85 & 30/51, if it does not, check fuse 1 , 3 and 20.
Edited by aide on Sunday 5th June 19:59