E34 535i heater blower only works on full?
E34 535i heater blower only works on full?
Author
Discussion

Bogracer

Original Poster:

438 posts

238 months

Thursday 17th November 2011
quotequote all
Hi working through the niggles, the heater blower only works on full not on the lower setting?

Hint, tips and fixes please?

Cheers,
James

johnfm

13,751 posts

281 months

Friday 18th November 2011
quotequote all
is it the Heater FSR?

Just about to replace mine - the fan is pulsing at most speeds except full an minimum.

It is a spiky looking thing (a resistor module with cooliing spikes). bout £24-40 part and a very tricky 1 hr job.

Pole84

595 posts

199 months

Friday 18th November 2011
quotequote all
Sounds like you need a new heater resistor.

You should be able to pick them up quite cheaply off ebay. Search for "hedgehog resistor"

Six Fiend

6,067 posts

246 months

Friday 18th November 2011
quotequote all
On mine it was the actual dial switch (the innards corrode), took it out and cleaned it up. Worked a bit then gave up properly so got a new one and job done smile

Here's the guide for sorting it out if it's not the switch:

http://www.bmwe34.net/E34main/Maintenance/Electric...

Frances The Mute

1,816 posts

272 months

Friday 18th November 2011
quotequote all
The E34 resistor unit is built in, so you'll need to replace the control panel.

They're a common failure point.