215 months

Tuesday 24th April 2012
quotequote all
Just been quoted £50+v for a re-gas. Guy said that if the pump cuts in (it does) it means there probably isn't a leak, it's just low refrigerant.

Is it common to pressure test an old system before re-gassing? He seemed surprised when I asked, and even more surprised when I asked if there was any kind of guarantee that it wouldn't need re-gassing in a few days (ie if they'd just re-gassed it and hoped for the best).

I'd assume that they could pressure test the system and have a fairly high degree of certainty that it wasn't going to dump the gas out after a few days. He seemed to think I was being a bit thick for even asking. Maybe I am, what does everyone else think?

Does anyone offer any form of warranty on re-gassing, or is it too risky since a part of the system could fail through natural wear and tear, or with the sudden increase in system pressure?

325Ti

391 posts

177 months

Friday 27th April 2012
quotequote all
in terms of warrenty the only one i've heard of was quick fit - if it doesnt make any difference then you dont pay

£50 is about right in terms of price i think - seen £50 to about £60 seeems standard

Ive an E46 as well - filled it up recently - but didnt need to pressure test it - as soon as it was connected it was easy to hear all the gas escaping

meaning i had a broken pipe and the garage quoted £250 to buy and fit a new one

so in terms of it escaping - I think it wold either escape very quickly or not at all

hope this helps

B3Svert

553 posts

223 months

Friday 27th April 2012
quotequote all
I think you can buy a can of gas from Halfords for £35, with £10 refunded when you take the empty can back. Seem to remember they also do a pressure test kit and leak fix kit.

bolide

582 posts

285 months

Friday 27th April 2012
quotequote all
He's right that if the compressor kicks in the system has gas and just needs topping up. But he's wrong about everything else

The machines that a/c guys use nowadays pull all the refrigerant and lubricant out of the system and keep it under vacuum for a minutes or so. If it holds vacuum they will regas it. If it doesn't hold vacuum you have a leak and the leak needs to be fixed before it is regassed

The refrigerant is dispensed by weight - there will be a standard weight for your system. So to top the system up you need to extract all the refrigerant and replace it with the correct weight. For that reason the top-up systems from Halfords, etc, are a waste of time & money

It's illegal to vent gases to atmosphere and all refrigerants have to be booked in & out in a complex system. There are huge penalties for failing to comply which makes the life of an a/c guy hard work. This is why there are dodgy people around who will gas up systems using propane from a Calor Gas bottle...

Nick Froome

dr_gn

Original Poster:

16,992 posts

215 months

Friday 27th April 2012
quotequote all
bolide said:
He's right that if the compressor kicks in the system has gas and just needs topping up. But he's wrong about everything else

The machines that a/c guys use nowadays pull all the refrigerant and lubricant out of the system and keep it under vacuum for a minutes or so. If it holds vacuum they will regas it. If it doesn't hold vacuum you have a leak and the leak needs to be fixed before it is regassed

The refrigerant is dispensed by weight - there will be a standard weight for your system. So to top the system up you need to extract all the refrigerant and replace it with the correct weight. For that reason the top-up systems from Halfords, etc, are a waste of time & money

It's illegal to vent gases to atmosphere and all refrigerants have to be booked in & out in a complex system. There are huge penalties for failing to comply which makes the life of an a/c guy hard work. This is why there are dodgy people around who will gas up systems using propane from a Calor Gas bottle...

Nick Froome
Thanks guys.

Yes, he said he'd connect it to a vac pump and evacuate all the old crap & moisture, then refill.

If he found a leak, then he wouldn't refill it. I therefore thought that if he *didn't* find a leak, and refilled it, why wouldn't there be some kind of warranty against it emptying overnight or within say a week?

The only reason I can think of is something failing under the pressure of new gas (as opposed to vacuum), which is fair enough, but what's to stop him finding a tiny leak, but filling it anyway and charging me £50 odd?

dandle

32 posts

183 months

Friday 27th April 2012
quotequote all
From chatting to an A/C installation guy yesterday the oil isnt replaced when regassing. The oil can be drained out and replaced or when refilling the system theres a certain amount of oil that should be replaced (topped up) as some of the oil will be lost with the gas either leaking or when its vacumed out. He was saying the majority of places will just add gas and no oil which doesnt always fix noisy compressors and the like.

PEJAYMotors

29 posts

175 months

Tuesday 1st May 2012
quotequote all
The reason for vacuuming the system is to pull out any moisture that might have found its way into the system but mainly it's too make fe filling the system a lot easier and faster as the refrigerant isn't put back under pressure it has to be pulled into the A/C system. The only problem with a vacuum test is if the system ha a leaky o-ring or small crack in a joint then pulling the pressure down can stop the leak thus giving a false reading. The only way test a system properly and be able to provide a garuntee (as I do) is a nitrogen pressure test, putting 6bar of nitrogen through any A/C system shows up the smallest of leaks!!

Although I can give a sort term garuntee that the gas won't escape for 7 days, I wil never say that your A/C system wil continue to work for the following 12months etc as the systems themselves are known to be very vulnerable too fatigue.

dr_gn

Original Poster:

16,992 posts

215 months

Tuesday 1st May 2012
quotequote all
PEJAYMotors said:
The reason for vacuuming the system is to pull out any moisture that might have found its way into the system but mainly it's too make fe filling the system a lot easier and faster as the refrigerant isn't put back under pressure it has to be pulled into the A/C system. The only problem with a vacuum test is if the system ha a leaky o-ring or small crack in a joint then pulling the pressure down can stop the leak thus giving a false reading. The only way test a system properly and be able to provide a garuntee (as I do) is a nitrogen pressure test, putting 6bar of nitrogen through any A/C system shows up the smallest of leaks!!

Although I can give a sort term garuntee that the gas won't escape for 7 days, I wil never say that your A/C system wil continue to work for the following 12months etc as the systems themselves are known to be very vulnerable too fatigue.
Understood, thanks. I'll get it done for £50 and see what happens. If it leaks at least I know I have t ofind a leak!