Braided fuel pipe
Discussion
Quick question regarding braided fuel pipe .. Does the clamp go over the braid or does it need to be cut back ? The hose clips do not like to tighten up over the braid ,in fact I have damaged both clamps by trying to get them reasonably tight .
The jubilee clips are now sprained..
They are made by sytec .

The jubilee clips are now sprained..
They are made by sytec .Edited by SILICONEKID350HP on Wednesday 3rd April 21:52
Daren,
The hose finisher size I use with my kit is AN-6.
This is fine with the Aeroquip braided fuel hose used.
These are cut to length with a special cintered blade but still require taping prior to cutting.
The finished cut is very clean and the tape help to prevent the braid unwrapping.
This may in fact be the problem.
Suggest you use pvc tape or heatsrink but try to draw out the braid to the cut ends using gloves.
Finally measure the OD of the hose.
The AN sizes actually relate to the ID of the hose which has no real relevance for hose finishers!
Call me if you want to discuss on 01484 607937
Best of luck John
The hose finisher size I use with my kit is AN-6.
This is fine with the Aeroquip braided fuel hose used.
These are cut to length with a special cintered blade but still require taping prior to cutting.
The finished cut is very clean and the tape help to prevent the braid unwrapping.
This may in fact be the problem.
Suggest you use pvc tape or heatsrink but try to draw out the braid to the cut ends using gloves.
Finally measure the OD of the hose.
The AN sizes actually relate to the ID of the hose which has no real relevance for hose finishers!
Call me if you want to discuss on 01484 607937
Best of luck John
jonnyZ said:
Daren,
The hose finisher size I use with my kit is AN-6.
This is fine with the Aeroquip braided fuel hose used.
These are cut to length with a special cintered blade but still require taping prior to cutting.
The finished cut is very clean and the tape help to prevent the braid unwrapping.
This may in fact be the problem.
Suggest you use pvc tape or heatsrink but try to draw out the braid to the cut ends using gloves.
Finally measure the OD of the hose.
The AN sizes actually relate to the ID of the hose which has no real relevance for hose finishers!
Call me if you want to discuss on 01484 607937
Best of luck John
Thanks ,I just think the jubilee style clips on the sytec clips are cheap ..I seem to get better results with a genuine jubilee clip and the rubber covers .
The hose finisher size I use with my kit is AN-6.
This is fine with the Aeroquip braided fuel hose used.
These are cut to length with a special cintered blade but still require taping prior to cutting.
The finished cut is very clean and the tape help to prevent the braid unwrapping.
This may in fact be the problem.
Suggest you use pvc tape or heatsrink but try to draw out the braid to the cut ends using gloves.
Finally measure the OD of the hose.
The AN sizes actually relate to the ID of the hose which has no real relevance for hose finishers!
Call me if you want to discuss on 01484 607937
Best of luck John
Thanks ,I just think the jubilee style clips on the sytec clips are cheap ..I seem to get better results with a genuine jubilee clip and the rubber covers .