fan on all the time
fan on all the time
Author
Discussion

pmanson

Original Poster:

13,388 posts

283 months

Wednesday 10th April 2013
quotequote all
Hi all,

Any idea of what would cause one of the two fans to run continuously? It started on Sunday.

Not driven the car since then, just been out and put the keys in the ignition and the fan cut in immediately.

Cheers,
Phill

chris1972

3,597 posts

167 months

Wednesday 10th April 2013
quotequote all
pmanson said:
Hi all,

Any idea of what would cause one of the two fans to run continuously? It started on Sunday.

Not driven the car since then, just been out and put the keys in the ignition and the fan cut in immediately.

Cheers,
Phill
Could it be the otter switch?

http://www.chimaerapages.com/resources_manual_fan....

Trevor450

1,937 posts

178 months

Wednesday 10th April 2013
quotequote all
Someone may have put a manual switch in. Sometimes they connect it the wiper stalk after putting in a stalk from a rear wash/wipe car or they connect it to the dash light switch. As above, it could also be the otter switch.

pmanson

Original Poster:

13,388 posts

283 months

Wednesday 10th April 2013
quotequote all
Thanks guys. I was standing by the car when it first cut in I guess the otter switch is the place to start.

I assume I'm OK to keep driving it?

Trevor450

1,937 posts

178 months

Wednesday 10th April 2013
quotequote all
Fan on all the time is better than not working, but keep an eye on the temperature guage.

pmanson

Original Poster:

13,388 posts

283 months

Wednesday 10th April 2013
quotequote all
That's good to know! Is it a TVR part or a standard Rover V8 part?

Trevor450

1,937 posts

178 months

Wednesday 10th April 2013
quotequote all
I think TVR may have used a slightly cooler one than Land Rover did.

pmanson

Original Poster:

13,388 posts

283 months

Wednesday 10th April 2013
quotequote all
Trevor450 said:
I think TVR may have used a slightly cooler one than Land Rover did.
Thanks, just ordered one from Clever Trevor.

Cheers

Engineer1949

1,423 posts

174 months

Wednesday 10th April 2013
quotequote all
as the otter switch controls both fans via a relay if it turns out to be the switch at fault looks like the other fan will need looking at.

john

pmanson

Original Poster:

13,388 posts

283 months

Wednesday 10th April 2013
quotequote all
Good point... both were certainly coming on the other day (I ran the car up to temp in the garage to test everything was working ok due to the cold weather).

pmanson

Original Poster:

13,388 posts

283 months

Saturday 13th April 2013
quotequote all
New switch has been delivered. Is there a way of getting the old one out without removing the swirl pot from the car / draining down the whole system?

buzzsaw

698 posts

299 months

Saturday 13th April 2013
quotequote all
pmanson said:
New switch has been delivered. Is there a way of getting the old one out without removing the swirl pot from the car / draining down the whole system?
When I changed mine I just unscrewed the old one and had the new one ready to put back in. Change it over quickly and you won't loose much coolant, then top up the swirl pot. Its also worthwhile wrapping some PTFE tape around the threads to prevent leaks.

David Beer

3,982 posts

297 months

Saturday 13th April 2013
quotequote all
I have never heard of an otter on all the time. Surely just unplug it to confirm before risking airlocks etc.

Aussie John

1,021 posts

261 months

Sunday 14th April 2013
quotequote all
Just replaced mine which measured short-circuit with wires off and cold in situ; but once I removed it the measurement was as it should [o/c] changed it anyway.

Chilliman

12,422 posts

191 months

Sunday 14th April 2013
quotequote all
I had this on mine, although IIRC it was one fan not both..had to disconnect the connecters to stop it, noticed they appeared corroded... cleaned them up, reconnected and the problem disappeared... possibly co-incidence..... Worth having a look though...

SILICONEKID350HP

14,997 posts

261 months

Sunday 14th April 2013
quotequote all
You can buy them in a range of temps ,coming off and on at two temperatures .I went for the cooler one which means it cuts in better in traffic ,less chance of over heating .

pmanson

Original Poster:

13,388 posts

283 months

Sunday 14th April 2013
quotequote all
buzzsaw said:
pmanson said:
New switch has been delivered. Is there a way of getting the old one out without removing the swirl pot from the car / draining down the whole system?
When I changed mine I just unscrewed the old one and had the new one ready to put back in. Change it over quickly and you won't loose much coolant, then top up the swirl pot. Its also worthwhile wrapping some PTFE tape around the threads to prevent leaks.
Struggling to get a socket/adjustable spanner on it with it in situ

buzzsaw

698 posts

299 months

Sunday 14th April 2013
quotequote all
pmanson said:
buzzsaw said:
pmanson said:
New switch has been delivered. Is there a way of getting the old one out without removing the swirl pot from the car / draining down the whole system?
When I changed mine I just unscrewed the old one and had the new one ready to put back in. Change it over quickly and you won't loose much coolant, then top up the swirl pot. Its also worthwhile wrapping some PTFE tape around the threads to prevent leaks.
Struggling to get a socket/adjustable spanner on it with it in situ
I think I used a ring ratchet spanner on mine

buzzsaw

698 posts

299 months

Sunday 14th April 2013
quotequote all
pmanson said:
buzzsaw said:
pmanson said:
New switch has been delivered. Is there a way of getting the old one out without removing the swirl pot from the car / draining down the whole system?
When I changed mine I just unscrewed the old one and had the new one ready to put back in. Change it over quickly and you won't loose much coolant, then top up the swirl pot. Its also worthwhile wrapping some PTFE tape around the threads to prevent leaks.
Struggling to get a socket/adjustable spanner on it with it in situ
I think I used a ring ratchet spanner on mine