My chimaera does not start when hot I have fitted the modwise relay kit so now its time for a new starter, is it a easy DIY or should I just pay to have it fitted, been quoted approx £200 for new starter and fitting.

peter miller

196 posts

281 months

Monday 31st January 2005
quotequote all
Sounds like the common problem of heat soak from the manifolds cooking the starter.
I had the same problem a couple of years ago, its starts fine when cold, but will let you down for a few minutes after stopping when hot.eg after filling at fuel station, an embarrising wait before it cools enough to turn over.
I removed my starter and stripped it apart and completely degreased it as well as the solonoid, and wrapped it in some heat shield material I purchased from a motorfactors. and it has been fine ever since.
It maybe worth a try before you fork out for a new starter.

>> Edited by peter miller on Monday 31st January 22:36

dlewis

315 posts

298 months

Monday 31st January 2005
quotequote all
Colin

That is not a bad price for a new one fitted!

You would need at least axles stands, some good leverage and sockets etc.

Dave

2 Smokin Barrels

32,006 posts

264 months

Monday 31st January 2005
quotequote all
If it's a newun, at £200 fitted I'd just get on with it. The bit you'd save by doing it yourself ain't worth the knuckle skinning!

colinrob

Original Poster:

1,199 posts

280 months

Monday 31st January 2005
quotequote all
Thanks for the replies I'll book it in and get it done

simon.b

1,230 posts

311 months

Tuesday 1st February 2005
quotequote all
Hang on a minute,

If you’ve got David’s kit fitted, check the feed into the new relay, you can use the LED.

I had the same problem and it turned out to be the META immobiliser relay that was cooking and not the starter. Moving the immobiliser sorted it.

Another check is to get under the car when hot and not starting, then with care short the solenoid to the starter motor power cable, if it turns over your starter is fine.

Cheers,

Simon.

2 Smokin Barrels

32,006 posts

264 months

Tuesday 1st February 2005
quotequote all
2 Smokin Barrels said:
If it's a newun, at £200 fitted I'd just get on with it. The bit you'd save by doing it yourself ain't worth the knuckle skinning!


Edited to say: If it is definitely required that is.

colinrob

Original Poster:

1,199 posts

280 months

Tuesday 1st February 2005
quotequote all
Does'nt the immobiliser also start the fuel pump as that is working fine, it is just the starter not turning, checked the wiring on the modwise kit all seems OK, have booked it in at Offords on Thursday I will ask them to double check that it is the starter.

simon.b

1,230 posts

311 months

Tuesday 1st February 2005
quotequote all
The original META system immobiliser has three separate circuits with an on board relay for each, one for the starter, one for the fuel pump and I forget what the third one is.

So yes, your fuel pump could still be running, been there.

Good luck,

Simon.

PS mail me direct if this is your problem.


>> Edited by simon.b on Tuesday 1st February 22:50

colinrob

Original Poster:

1,199 posts

280 months

Thursday 3rd February 2005
quotequote all
Simon YHM