100A fuse: is it really 100A?
Discussion
It has 100A stamped on it... no idea what that actually signifies but I assume all such fuses will be rated according to a consistent system and you will be replacing like-for-like by fitting a replacement of the same marked value.
I asked the same Q a little while ago and don't think it got a definitive response.
I asked the same Q a little while ago and don't think it got a definitive response.
Andy,
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.
Just my tuppence.
Cheers
Paul
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.
Just my tuppence.
Cheers
Paul
Paulathome said:
Andy,
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.
Just my tuppence.
Cheers
Paul
A 100 amp fuse is designed to take 100 amps continuous.
However if you look more deeply into the technical side of fuses, say a mains fuse for instance they will also have a time related measurement.
ie a mains fuse rated at 13 amps may take 30 amps for 2 seconds or 50 amps for one second before it blows. It would also take maybe 100 amps for several milliseconds before failure.
Based on this information I would imagine that our 100 amp fuse would probably pass 200 or maybe three hundred amps for a couple of seconds.
Just my tuppence.
Cheers
Paul