Power Steering Reservoir
Discussion
In the four years I've owned my Chimaera, I've never managed to keep the power steering fluid in the reservoir - the damn stuff gets everywhere, despite multiple attempts by various menders, so I'd like to start again;
- I assume the hose is available from any old motor factor?
- Which car is the reservoir from? Or better still, does anyone make an alloy replacement?
- I'd really like to relocate the reservoir somewhere other than on top of the engine, so if it does leak, the fluid doesn't run down into the valley. But where? (It's a '97 450, serpentine.) There doesn't seem to be anywhere it can go (which is presumably why TVR put it where it is...) I think I've seen them mounted on the front crossmember, but I can't find the photos.
- Does the reservoir have to be above the pump?
- I assume the hose is available from any old motor factor?
- Which car is the reservoir from? Or better still, does anyone make an alloy replacement?
- I'd really like to relocate the reservoir somewhere other than on top of the engine, so if it does leak, the fluid doesn't run down into the valley. But where? (It's a '97 450, serpentine.) There doesn't seem to be anywhere it can go (which is presumably why TVR put it where it is...) I think I've seen them mounted on the front crossmember, but I can't find the photos.
- Does the reservoir have to be above the pump?
Hose SAE100R6 is the stuff to use on the low pressure side, 1/2" from the rack back to the reservoir, 5/8" from the reservoir to the pump. For the high pressure feed I went to my local Pirtek and they made up a high pressure hose for me and gave me adaptors to get rid of the banjo fitting (apparently banjos the spawn of Satan in the hydraulics business).
As mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain
As mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain
Yes, 1/2" and 5/8" are both standard sizes of hose. See the Pirtek catalogue http://www.pirtek.co.uk/pdf/catalogue_sections/cat...
Regards
Iain
Regards
Iain
Chassis 33 said:
Hose SAE100R6 is the stuff to use on the low pressure side, 1/2" from the rack back to the reservoir, 5/8" from the reservoir to the pump. For the high pressure feed I went to my local Pirtek and they made up a high pressure hose for me and gave me adaptors to get rid of the banjo fitting (apparently banjos the spawn of Satan in the hydraulics business).
As mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain
With the standard reservoir,if you put it lower than the pump fluid will piss out as the cap is ventedAs mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain

That Daddy said:
Chassis 33 said:
Hose SAE100R6 is the stuff to use on the low pressure side, 1/2" from the rack back to the reservoir, 5/8" from the reservoir to the pump. For the high pressure feed I went to my local Pirtek and they made up a high pressure hose for me and gave me adaptors to get rid of the banjo fitting (apparently banjos the spawn of Satan in the hydraulics business).
As mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain
With the standard reservoir,if you put it lower than the pump fluid will piss out as the cap is ventedAs mentioned the reservoir is fairly generic, its the same a Landrovers (which have the reservoir mounted to the side of the radiator)
I've asked the question about relocating before and while logic says it need to be above the pump to make it self prime etc the Griff owner who has relocated it to the front crossmember says it doesn't cause any issues
Regards
Iain


Gassing Station | Chimaera | Top of Page | What's New | My Stuff






