fuel pump relays
fuel pump relays
Author
Discussion

barrybike

Original Poster:

33 posts

274 months

Friday 10th April 2009
quotequote all
have an intermittant starting problem and suspect faulty relays, when the ignition is on should all the pins on the 2 relays be live ??? also do you have to use metal relays as the bosch replacement ones are now plastic??.

scotty_d

6,795 posts

225 months

Friday 10th April 2009
quotequote all
barrybike said:
have an intermittant starting problem and suspect faulty relays, when the ignition is on should all the pins on the 2 relays be live ??? also do you have to use metal relays as the bosch replacement ones are now plastic??.
No they dont have to be metal, but they do have to have the correct diodes in them.

barrybike

Original Poster:

33 posts

274 months

Friday 10th April 2009
quotequote all
best place to get the correct ones from ????

Cider Andy

1,889 posts

256 months

Friday 10th April 2009
quotequote all
barrybike said:
when the ignition is on should all the pins on the 2 relays be live?
No. With the engine running all terminals on both relays should be at 12V except 85. With just the ignition on and the engine not running (ie. with the fuel pump stopped) 30, 86 and 85 should be at 12V, 87 and 87a should be at 0V (on the fuel pump relay).

It's only possible to have all terminals at 12V if the relay is faulty (stuck in the closed position).

bone

27 posts

230 months

Friday 10th April 2009
quotequote all
hi,just replaced my fuel pump relay i just gave my local bosch agent the part number on top of relay and they got me a new one like for like(metal)cost less than £7 can give you there number if you want.

barrybike

Original Poster:

33 posts

274 months

Tuesday 14th April 2009
quotequote all
thanks for that bone, let me have the part number, sse if its the same as the BMW one cheers barry

BrianMillar

192 posts

236 months

Wednesday 15th April 2009
quotequote all
scotty_d said:
barrybike said:
have an intermittant starting problem and suspect faulty relays, when the ignition is on should all the pins on the 2 relays be live ??? also do you have to use metal relays as the bosch replacement ones are now plastic??.
No they dont have to be metal, but they do have to have the correct diodes in them.
I opened one of my old relays up to have a look. I could not see any diodes in it.

My intention was to replace the relay with a 40 or 50 amp one (original Bosch relay is 30A) to see if it would cope better. However, they are different to a standard relay two of the connectors are shorted together where on a standard relay they are open circuit. I am not at home at the moment so I can't check to see which the shorted conectors are.

350Matt

3,915 posts

310 months

Wednesday 15th April 2009
quotequote all
I think the problem with these is the way they float around on the end of the harness so get rattled about rather than they can't cope with the current